{"id":4517,"date":"2026-11-20T08:29:01","date_gmt":"2026-11-20T07:29:01","guid":{"rendered":"https:\/\/anogas.com\/?p=4517"},"modified":"2026-11-20T08:29:01","modified_gmt":"2026-11-20T07:29:01","slug":"how-do-you-choose-a-fire-suppression-agent-for-industrial-use","status":"publish","type":"blog","link":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/","title":{"rendered":"How do you choose a fire suppression agent for industrial use?"},"content":{"rendered":"<p>Choosing a fire suppression agent for industrial use means matching the agent&#8217;s performance to the fire risks in your facility, your regulatory obligations, and the infrastructure you already have. The right choice depends on the fire classes you face, the environmental and safety standards you must meet, and whether your risks include lithium-ion battery fires. The sections below cover the key questions that shape a sound selection decision.<\/p>\n<h2>What types of fire risks are most common in industrial environments?<\/h2>\n<p>Industrial environments typically face fire risks across several classes at once: Class A fires involving solid combustibles such as wood, paper, and textiles; Class B fires involving flammable liquids and fuels; and, increasingly, fires involving lithium-ion battery systems. The mix depends on the sector. Warehousing, manufacturing, recycling, and energy storage facilities each carry distinct risk profiles that influence which suppression agent is appropriate.<\/p>\n<p>One of the fastest-growing industrial fire risks in 2026 is thermal runaway in lithium-ion battery systems. Electric vehicles, forklifts, energy storage units, e-bikes, and power tools are now present in a wide range of industrial settings. When a lithium-ion cell is mechanically damaged, overcharged, or exposed to excessive heat, it can enter thermal runaway. This is a self-sustaining reaction in which rising temperature causes internal materials to decompose, releasing flammable gases such as hydrogen and methane, along with toxic and corrosive hydrogen fluoride. Heat from one failing cell transfers to neighbouring cells and can trigger a cascading sequence that conventional suppression approaches may struggle to interrupt.<\/p>\n<p>Recycling facilities face a compounded version of this challenge, because incoming waste streams often contain batteries of unknown condition. Maritime environments combine fuel fire risks with confined spaces. Warehouses storing mixed goods face multi-class scenarios in which a single agent must perform across fire types. Mapping these risks accurately is the first step before any suppression agent can be evaluated.<\/p>\n<h2>What are the key criteria for selecting an industrial fire suppression agent?<\/h2>\n<p>The key criteria are effectiveness across the fire classes present in your facility, compatibility with your existing suppression infrastructure, regulatory compliance including PFAS legislation, safety for people and the environment, and total lifecycle cost. No single criterion overrides the others. A highly effective agent that fails a regulatory test is not viable, and a compliant agent that cannot control your primary fire risk provides no real protection.<\/p>\n<p>Working through these criteria in a structured way produces a shortlist rather than a single automatic answer. Assess each in turn:<\/p>\n<ul>\n<li><strong>Fire class coverage:<\/strong> Confirm that the agent suppresses the fire types present: solid combustibles, flammable liquids, cooking fats, or lithium-ion battery fires.<\/li>\n<li><strong>Suppression mechanism:<\/strong> Compare whether the agent cools, smothers, interrupts chemical chain reactions, or combines mechanisms. For lithium-ion battery fires, sustained cooling and reignition risk are especially important.<\/li>\n<li><strong>Infrastructure compatibility:<\/strong> Verify with your system supplier and engineers whether the agent can be used in your existing sprinkler or suppression system, and what modifications or approvals would be needed.<\/li>\n<li><strong>Regulatory compliance:<\/strong> Check that the agent meets current and forthcoming European chemical regulations, particularly regarding PFAS.<\/li>\n<li><strong>Environmental and human safety:<\/strong> Confirm how the agent is classified for the environment and for people under applicable chemical law.<\/li>\n<li><strong>Certification:<\/strong> Confirm which tests the agent has passed and their scope. For example, NTA 8133 (KIWA) is a test standard for lithium-ion battery fire suppression. A result applies to the specific extinguisher model and test conditions, not to every installation.<\/li>\n<li><strong>Operational efficiency:<\/strong> Establish how much agent is needed per incident, and what the cleanup and disposal requirements are.<\/li>\n<\/ul>\n<p>Where lithium-ion battery fire risk is present, the suppression mechanism criterion deserves particular weight. An agent that extinguishes visible flames does not necessarily end internal heating or gas release, so the battery system can remain in a dangerous intermediate state with a risk of reignition. Understanding <a href=\"https:\/\/anogas.com\/how-hydrogel-works\/\">how suppression mechanisms work<\/a> helps industrial buyers make a more informed comparison.<\/p>\n<div style=\"box-sizing !important;margin:0 auto !important;padding:22px 24px !important;max-width:620px !important;width:100% !important;font-family,Arial,Helvetica,sans-serif !important;color:#ffffff !important;line-height:1.5 !important;background:#008aa4 !important;border:2px solid #008aa4 !important;border-radius:2px !important;text-align !important\">\n<div style=\"box-sizing !important;margin:0 0 6px 0 !important;padding:0 !important;font-family,Arial,Helvetica,sans-serif !important;color:#ffffff !important;font-size:20px !important;font-weight:700 !important;line-height:30px !important;text-align !important\">See where Hydrogel fits your fire-safety strategy<\/div>\n<div style=\"box-sizing !important;margin:0 auto 16px auto !important;padding:0 !important;max-width:520px !important;font-family,Arial,Helvetica,sans-serif !important;color:#ffffff !important;font-size:16px !important;font-weight:300 !important;line-height:26px !important;text-align !important\">From lithium-ion batteries to existing water-based suppression systems, speak with Anogas about your application.<\/div>\n<p><a href=\"https:\/\/anogas.com\/contact\/\" style=\"box-sizing !important;display !important;margin:0 !important;padding:8px 20px 10px !important;font-family,Arial,Helvetica,sans-serif !important;color:#008aa4 !important;background:#ffffff !important;border:2px solid #ffffff !important;border-radius:0 !important;font-size:18px !important;font-weight:600 !important;line-height:26px !important;text-align !important;text-decoration !important\">Discuss your application<\/a>\n<\/div>\n<h2>What&#8217;s the difference between water, foam, and hydrogel suppression agents?<\/h2>\n<p>Water cools fires effectively but runs off hot surfaces quickly, which limits sustained contact with the fire source. Foam adds a smothering layer that suppresses vapour release and restricts oxygen access, but many foam formulations contain PFAS, which are now being phased out under European regulation. Hydrogel is a water-based agent containing modified natural clay. It cools like water, but its viscosity increases on contact with heat, which is intended to keep the agent on hot surfaces for longer.<\/p>\n<h3>Water as a suppression agent<\/h3>\n<p>Water remains the most widely used industrial suppression medium because it is inexpensive, widely available, and effective at absorbing heat. Its limitation is physical: it flows away from hot surfaces rapidly, which reduces sustained contact and cooling efficiency. For lithium-ion battery fires, water can suppress visible flames, but it may not provide enough sustained cooling to prevent reignition or interrupt thermal propagation between cells. Large volumes are typically needed, which generates significant contaminated runoff.<\/p>\n<h3>Foam as a suppression agent<\/h3>\n<p>Foam extends water&#8217;s performance by adding a blanket layer that limits oxygen access and suppresses vapour from flammable liquids. Aqueous film-forming foams have been used in industrial and aviation settings for decades. However, many formulations rely on PFAS compounds for their film-forming properties. As European regulation tightens and a full ban on PFAS-containing agents approaches, PFAS-based foam is becoming a less viable long-term choice for facilities that must remain compliant.<\/p>\n<h3>Hydrogel as a suppression agent<\/h3>\n<p>Hydrogel is composed of water and modified natural clay. It has low viscosity at ambient temperature and thickens on contact with heat, so it tends to cling to hot surfaces rather than run off. This sustained contact improves cooling, can reduce the volume of agent required, and helps limit heat transfer between adjacent battery cells. Hydrogel is formulated without PFAS and is classified as non-dangerous for the environment and humans under European chemical law. Because it is designed to be used in the same way as water, it may be suitable for existing water-based systems. This still needs to be confirmed through engineering and approval checks for each installation. Anogas&#8217;s <a href=\"https:\/\/anogas.com\/hydrogel\/\">Hydrogel product<\/a> is supplied as a ready-to-use premix, requiring no dilution or on-site preparation.<\/p>\n<p>Hydrogel is the agent for cooling and initial fire suppression. For longer-term containment intended to help prevent reignition of damaged or extinguished batteries, Anogas offers Hydrogel Shield. For cold-temperature applications, Hydrogel SubZ is a frost-protected formulation. Each has a distinct role within a wider fire-safety response.<\/p>\n<h2>How does PFAS legislation affect industrial fire suppression choices?<\/h2>\n<p>PFAS legislation is narrowing the range of compliant suppression agents available to industrial facilities. European Regulation (EU) 2025\/1988 is phasing out PFAS-containing extinguishing agents, with a complete ban expected by 2031. Facilities that currently use PFAS-based foam face a regulatory deadline that makes replacement a matter of compliance, not preference.<\/p>\n<p>PFAS (per- and polyfluoroalkyl substances) are highly persistent compounds that do not break down naturally in the environment. They can contaminate soil and groundwater and accumulate in living organisms, which is why regulators are prioritising their elimination. For industrial buyers, this has two practical consequences.<\/p>\n<p>First, evaluate any suppression agent selected today for compliance through its expected service life, not only for current compliance. An agent that is permitted now but banned before the end of its operational period will need early replacement, adding cost and disruption. Second, assess PFAS-free alternatives on performance as well as regulatory grounds, to confirm they meet the facility&#8217;s fire control requirements.<\/p>\n<p>Testing of Hydrogel has not detected PFAS above 1 part per billion, the limit of the analytical method used. Non-detection at that limit is not proof of absolute absence, and PFAS-free status says nothing in itself about firefighting performance or approvals, which must be assessed separately. Facilities that move to a PFAS-free agent now reduce the risk of a forced transition close to the 2031 deadline.<\/p>\n<h2>Which suppression agents work for lithium-ion battery fires?<\/h2>\n<p>Lithium-ion battery fires call for an agent that cools the fire source quickly, stays in contact with hot battery surfaces, and helps limit thermal propagation between cells. Reignition risk must also be managed. Water can control flames and cool, but it runs off hot surfaces quickly and typically needs large volumes. PFAS-based foams face regulatory restrictions. Hydrogel is designed to address these limitations through cooling and heat-responsive viscosity, and it has been tested to NTA 8133 in a specific portable extinguisher configuration.<\/p>\n<p>The central challenge is that the energy sustaining the incident comes from reactions inside the cells, not only from external combustion. Thermal runaway can produce temperatures in the range of 850 to 1,500 degrees Celsius. Gas release, including flammable hydrogen and methane and toxic hydrogen fluoride, can continue after visible flames are out. Suppressing flames therefore does not mean the battery is stable.<\/p>\n<p>Hydrogel works mainly by cooling and by staying in contact with hot surfaces. This helps suppress flames, reduce heat transfer between neighbouring cells, and limit gas and heat release at the surface. How far it can act depends on access: an externally applied agent may not reach cells inside an enclosed pack, and it will not necessarily stop every internal reaction. Performance depends on battery configuration, enclosure design, agent delivery, and the available test evidence. Hydrogel can also be used alongside other measures, such as Hydrogel Shield for longer-term containment of damaged batteries.<\/p>\n<p>After the fire, the hazard continues. Residual heat, gas release, and the risk of reignition can persist, so facilities should plan for monitoring, restricted access, and safe handling of damaged batteries. Extinguishment does not mean a battery is safe to reuse, store, transport, or dispose of.<\/p>\n<p>Agent quantity depends on the installation. As indicative guidance only, around 25 to 50 litres may suit smaller industrial installations, and 300 to 10,000 litres or more may apply to large-scale battery safety systems. These figures are application-specific and must be confirmed through risk assessment and engineering design. Hydrogel can be used in <a href=\"https:\/\/anogas.com\/fire-suppression-systems\/\">fixed fire suppression systems<\/a> as well as handheld extinguishers, subject to system compatibility, nozzle and discharge arrangement, coverage, and any required approvals.<\/p>\n<h2>When should an industrial facility switch its fire suppression agent?<\/h2>\n<p>An industrial facility should consider switching its fire suppression agent when the current agent no longer matches the fire risks present, when regulatory changes make it non-compliant, when new operations or equipment introduce fire classes it cannot handle, or when its service life is nearing its end. Any one of these conditions justifies a formal review.<\/p>\n<p>Several specific triggers are prompting industrial facilities to reassess their suppression agent choices in 2026:<\/p>\n<ul>\n<li><strong>Introduction of lithium-ion battery systems:<\/strong> Installing EV charging points, battery energy storage systems, or battery-powered equipment changes the facility&#8217;s fire risk profile. If the existing agent was not selected with battery fires in mind, review it.<\/li>\n<li><strong>PFAS regulatory timeline:<\/strong> Facilities using PFAS-based foam should plan their transition now, ahead of the 2031 ban, to avoid a rushed switch under compliance pressure.<\/li>\n<li><strong>Agent service life:<\/strong> Suppression agents have defined operational lifetimes, and Hydrogel&#8217;s is stated as more than ten years. When an agent nears the end of its rated life, compare the full range of current options instead of defaulting to a like-for-like replacement.<\/li>\n<li><strong>Operational changes:<\/strong> New product lines, changed storage configurations, or new industrial processes can alter the fire risk profile enough to require a different suppression approach.<\/li>\n<li><strong>Incident experience:<\/strong> If an agent has underperformed in use, particularly through reignition or environmental impact, reassess your choice.<\/li>\n<\/ul>\n<p>The transition need not be disruptive, but it should not be assumed to be straightforward. Hydrogel is designed to be used like water, so some water-based systems may accept it without modification. Do not assume that an existing sprinkler system will work with Hydrogel. Verify compatibility, including nozzle and discharge arrangement, coverage, operating temperature, and any required approvals, with the system supplier and your engineers. Mandatory fire protection, including marine fire protection, must not be replaced or modified without engineering and approval checks. For facilities that rely on <a href=\"https:\/\/anogas.com\/mobile-and-hand-held-fire-extinguishers\/\">portable extinguishers<\/a> for first response, moving to a Hydrogel-based unit is a simpler step, provided the extinguisher model is appropriate for the application.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Learn how to match fire suppression agents to industrial risks, including lithium-ion battery fires and PFAS compliance.<\/p>\n","protected":false},"author":4,"featured_media":0,"template":"","categories":[],"tags":[],"class_list":["post-4517","blog","type-blog","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How do you choose a fire suppression agent for industrial use? - Anogas<\/title>\n<meta name=\"description\" content=\"Choosing an industrial fire suppression agent means matching performance to your risks. Compare water, foam, and hydrogel, and find the compliant choice for 2026.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do you choose a fire suppression agent for industrial use? - Anogas\" \/>\n<meta property=\"og:description\" content=\"Choosing an industrial fire suppression agent means matching performance to your risks. Compare water, foam, and hydrogel, and find the compliant choice for 2026.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/\" \/>\n<meta property=\"og:site_name\" content=\"Anogas\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/\"},\"author\":{\"name\":\"Harry Verbakel\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#\\\/schema\\\/person\\\/dd067f7cd26fdfc65eac33d6bedaa6b3\"},\"headline\":\"How do you choose a fire suppression agent for industrial use?\",\"datePublished\":\"2026-11-20T07:29:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/\"},\"wordCount\":2021,\"inLanguage\":\"nl-NL\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/\",\"url\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/\",\"name\":\"How do you choose a fire suppression agent for industrial use? - Anogas\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#website\"},\"datePublished\":\"2026-11-20T07:29:01+00:00\",\"description\":\"Choosing an industrial fire suppression agent means matching performance to your risks. Compare water, foam, and hydrogel, and find the compliant choice for 2026.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/anogas.com\\\/nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blogs\",\"item\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How do you choose a fire suppression agent for industrial use?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/anogas.com\\\/nl\\\/\",\"name\":\"Anogas\",\"description\":\"Anogas Hydrogel: the different fire-extinguishing\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/anogas.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#\\\/schema\\\/person\\\/dd067f7cd26fdfc65eac33d6bedaa6b3\",\"name\":\"Harry Verbakel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g\",\"caption\":\"Harry Verbakel\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How do you choose a fire suppression agent for industrial use? - Anogas","description":"Choosing an industrial fire suppression agent means matching performance to your risks. Compare water, foam, and hydrogel, and find the compliant choice for 2026.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/","og_locale":"nl_NL","og_type":"article","og_title":"How do you choose a fire suppression agent for industrial use? - Anogas","og_description":"Choosing an industrial fire suppression agent means matching performance to your risks. Compare water, foam, and hydrogel, and find the compliant choice for 2026.","og_url":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/","og_site_name":"Anogas","twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"10 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/#article","isPartOf":{"@id":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/"},"author":{"name":"Harry Verbakel","@id":"https:\/\/anogas.com\/nl\/#\/schema\/person\/dd067f7cd26fdfc65eac33d6bedaa6b3"},"headline":"How do you choose a fire suppression agent for industrial use?","datePublished":"2026-11-20T07:29:01+00:00","mainEntityOfPage":{"@id":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/"},"wordCount":2021,"inLanguage":"nl-NL"},{"@type":"WebPage","@id":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/","url":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/","name":"How do you choose a fire suppression agent for industrial use? - Anogas","isPartOf":{"@id":"https:\/\/anogas.com\/nl\/#website"},"datePublished":"2026-11-20T07:29:01+00:00","description":"Choosing an industrial fire suppression agent means matching performance to your risks. Compare water, foam, and hydrogel, and find the compliant choice for 2026.","breadcrumb":{"@id":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/anogas.com\/nl\/blog\/how-do-you-choose-a-fire-suppression-agent-for-industrial-use\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/anogas.com\/nl\/"},{"@type":"ListItem","position":2,"name":"Blogs","item":"https:\/\/anogas.com\/nl\/blog\/"},{"@type":"ListItem","position":3,"name":"How do you choose a fire suppression agent for industrial use?"}]},{"@type":"WebSite","@id":"https:\/\/anogas.com\/nl\/#website","url":"https:\/\/anogas.com\/nl\/","name":"Anogas","description":"Anogas Hydrogel: the different fire-extinguishing","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/anogas.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Person","@id":"https:\/\/anogas.com\/nl\/#\/schema\/person\/dd067f7cd26fdfc65eac33d6bedaa6b3","name":"Harry Verbakel","image":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/secure.gravatar.com\/avatar\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g","caption":"Harry Verbakel"}}]}},"_links":{"self":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog\/4517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/types\/blog"}],"author":[{"embeddable":true,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/users\/4"}],"version-history":[{"count":4,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog\/4517\/revisions"}],"predecessor-version":[{"id":5235,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog\/4517\/revisions\/5235"}],"wp:attachment":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/media?parent=4517"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/categories?post=4517"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/tags?post=4517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}