{"id":4831,"date":"2026-11-21T08:00:00","date_gmt":"2026-11-21T07:00:00","guid":{"rendered":"https:\/\/anogas.com\/?p=4831"},"modified":"2026-11-13T11:22:12","modified_gmt":"2026-11-13T10:22:12","slug":"what-is-thermal-runaway-and-can-it-be-stopped-onboard","status":"publish","type":"blog","link":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/","title":{"rendered":"What is thermal runaway and can it be stopped onboard?"},"content":{"rendered":"<p>A lithium-ion battery fire onboard can remain hazardous after the visible flames are out, because heat-generating reactions may continue inside the cells. That self-heating chain reaction is thermal runaway. Onboard safeguards can reduce the chance of failure and limit its spread, but flame suppression alone does not show that affected cells are stable. Cooling, containment and continued monitoring address different parts of the hazard.<\/p>\n<h2>What is thermal runaway in a battery?<\/h2>\n<p>Thermal runaway is a self-heating chain reaction within a lithium-ion cell. As <a href=\"https:\/\/anogas.com\/thermal-runaway-blocker\/\">heat-generating reactions<\/a> raise its temperature, they drive further reactions. The energy sustaining a battery fire can come from within the cells. Removing an external flame may therefore leave the cause of reignition in place.<\/p>\n<p>A failing cell can also transfer heat to its neighbours. If those cells fail in turn, a single-cell event can become a pack-level incident. The distinction matters onboard. Suppressing combustion at the first cell and preventing failure elsewhere in the installation are related but separate tasks.<\/p>\n<h2>What triggers thermal runaway?<\/h2>\n<p>Overcharging, rapid charging, physical impact, external heat, internal short circuits and manufacturing defects can all lead to lithium-ion battery failure. They do not follow the same electrical pathway. A protection device that responds to one condition therefore cannot cover every cause of thermal runaway.<\/p>\n<p>For example, a <a href=\"https:\/\/ul.org\/research-updates\/what-keeps-lithium-ion-batteries-safe\/\" target=\"_blank\" rel=\"noopener noreferrer\">positive temperature coefficient device<\/a> increases resistance when it becomes unusually hot, reducing current into and out of a cell. A current interrupt device disconnects electrically when gas produced during overcharge or overvoltage raises internal pressure. Both address defined fault conditions. Neither makes a cell immune to damage or external heating.<\/p>\n<div style=\"box-sizing:border-box !important;margin:0 auto !important;padding:22px 24px !important;max-width:620px !important;width:100% !important;font-family:Arial,Helvetica,sans-serif !important;color:#ffffff !important;line-height:1.5 !important;background:#008aa4 !important;border:2px solid #008aa4 !important;border-radius:2px !important;text-align:center !important;\">\n<div style=\"box-sizing:border-box !important;margin:0 0 6px 0 !important;padding:0 !important;font-family:Arial,Helvetica,sans-serif !important;color:#ffffff !important;font-size:20px !important;font-weight:700 !important;line-height:30px !important;text-align:center !important;\">See where Hydrogel fits your fire-safety strategy<\/div>\n<div style=\"box-sizing:border-box !important;margin:0 auto 16px auto !important;padding:0 !important;max-width:520px !important;font-family:Arial,Helvetica,sans-serif !important;color:#ffffff !important;font-size:16px !important;font-weight:300 !important;line-height:26px !important;text-align:center !important;\">From lithium-ion batteries to existing water-based suppression systems, speak with Anogas about your application.<\/div>\n<p><a href=\"https:\/\/anogas.com\/contact\/\" style=\"box-sizing:border-box !important;display:inline-block !important;margin:0 !important;padding:8px 20px 10px !important;font-family:Arial,Helvetica,sans-serif !important;color:#008aa4 !important;background:#ffffff !important;border:2px solid #ffffff !important;border-radius:0 !important;font-size:18px !important;font-weight:600 !important;line-height:26px !important;text-align:center !important;text-decoration:none !important;\">Discuss your application<\/a>\n<\/div>\n<h2>What happens inside a cell as thermal runaway develops?<\/h2>\n<p>A polymer separator normally allows ions to pass while keeping the positive and negative electrodes electrically apart. As a cell failure develops, self-heating can be followed by separator failure, an internal short circuit and the release of flammable and toxic gases.<\/p>\n<p>These processes occur within the cell. An extinguished flame shows that visible combustion has been controlled at that point. It does not show that the separator is intact, that internal reactions have ended or that the cell has stopped releasing heat.<\/p>\n<h2>How can thermal runaway spread to neighbouring cells?<\/h2>\n<p>Heat transferred from one failing cell can raise the temperature of adjacent cells until they fail too. In a <a href=\"https:\/\/portal.fis.tum.de\/en\/publications\/thermal-runaway-propagation-in-automotive-lithium-ion-batteries-w\/\" target=\"_blank\" rel=\"noopener noreferrer\">peer-reviewed automotive-battery comparison<\/a>, the researchers identified cell spacing, materials between cells and cell-stack arrangement as factors affecting propagation. Across the full propagation interval they examined, thermal runaway progressed five times faster in the tested NMC-811 batteries than in the tested LFP batteries.<\/p>\n<p>That difference is useful when assessing chemistry, but the pack&#8217;s physical design also matters. For an onboard installation, assess where heat can travel from the first affected cell, not only where flames might appear.<\/p>\n<h2>Do LFP batteries suffer from thermal runaway?<\/h2>\n<p>LFP cells can undergo thermal runaway, and a failure can propagate through a pack. In the NMC-811 and LFP comparison, the reaction speed at cell level was nine times faster for the tested NMC-811 cells than for the tested LFP cells. The researchers found higher safety requirements for the graphite\u2013NMC-811 chemistry they examined.<\/p>\n<p>That is a reason to consider chemistry during battery selection. It is not a reason to treat LFP as exempt from thermal runaway prevention. The researchers also describe a trade-off between safety and energy density when chemistry is integrated into a pack. Cell arrangement and the materials between cells still need assessment for the particular installation.<\/p>\n<h2>Can thermal runaway be stopped onboard once it starts?<\/h2>\n<p>An onboard response can cool a burning battery, suppress flames and work to limit heat transfer to neighbouring cells. It cannot treat the disappearance of visible flames as proof that reactions inside affected cells have stopped. Continued monitoring remains part of the response because residual heat can support reignition.<\/p>\n<p><a href=\"https:\/\/anogas.com\/hydrogel\/\">Hydrogel<\/a> is a water-based agent containing modified natural clay. Its viscosity rises with temperature, which is intended to keep the agent in contact with hot surfaces and retain cooling capacity at the fire source. The water content provides cooling, while the clay forms a barrier to oxygen and flammable gases. Foamed Hydrogel can also adhere to hot solid surfaces, including vertical walls and ceilings. These properties support cooling and initial fire suppression. Anogas positions Hydrogel for maritime battery fires.<\/p>\n<p>Its reach has limits. An externally applied agent does not necessarily reach cells inside an enclosed pack, and it does not stop every internal reaction. Performance depends on access to the battery, the battery configuration and the delivery method. Applying the agent does not replace containment of neighbouring cells or monitoring after suppression.<\/p>\n<h2>How can onboard systems help prevent or contain thermal runaway?<\/h2>\n<p>Thermal runaway prevention begins before a fire. Cell protections and a battery management system address faults at different levels. Installed firefighting equipment addresses heat and combustion after a failure. For a vessel specification, these layers call for separate checks:<\/p>\n<ul>\n<li><strong>Identify the fault protections.<\/strong> Confirm which cell-level measures are present, such as the separator, positive temperature coefficient device and current interrupt device. Confirm what the battery management system controls at battery level. Electrical protection is not the same as a plan for cooling a failed cell.<\/li>\n<li><strong>Match the response to the installation.<\/strong> Anogas markets Hydrogel for electric and hybrid vessels, onboard battery rooms and energy storage, cargo protection and mobile response. The agent is designed to be compatible with water-based suppression systems and can be foamed in a mobile extinguisher or at a sprinkler nozzle. Do not assume an existing sprinkler system works with Hydrogel. Verify the enclosure design, agent quantity, nozzle and discharge arrangement, and coverage, and confirm that the delivery method reaches the relevant hazard.<\/li>\n<li><strong>Check operating conditions and storage.<\/strong> The HydroGel BM 048 technical data sheet lists a freezing temperature of 0\u00b0C, an application ambient temperature above 5\u00b0C and a recommended storage period of no more than 60 months from delivery in the original package. Check these limits against the actual vessel location.<\/li>\n<li><strong>Verify the intended use.<\/strong> The same data sheet calls for users to test the agent for their own intended purpose and does not warrant fitness for a particular purpose. Compatibility with existing infrastructure is a starting point. Assess the proposed system and battery arrangement together, and confirm the engineering and approval route before modifying any mandatory marine fire protection.<\/li>\n<\/ul>\n<h2>What hazards remain after the visible flames are out?<\/h2>\n<p>Residual heat in affected cells can lead to reignition. A failing cell may also release gases including <a href=\"https:\/\/anogas.com\/blog\/why-lithium-ion-battery-fires-are-a-growing-safety-risk\/\">hydrogen, methane and hydrogen fluoride<\/a>. Flame suppression therefore does not settle the questions of gas exposure or the condition of adjacent cells.<\/p>\n<p>Cooling can reduce the heat available to drive further failure, and a barrier to flammable gases may reduce exposure at the application point. Neither eliminates the gas hazard. Monitor affected cells, neighbouring cells and the surrounding space rather than relying on flame status alone. Restrict access until conditions are verified. Extinguishment does not mean the battery is safe to reuse, store, transport or dispose of.<\/p>\n<h2>What does an NTA 8133 extinguisher test establish?<\/h2>\n<p><a href=\"https:\/\/www.nen.nl\/en\/nta-8133-2021-a1-2025-en-335012\" target=\"_blank\" rel=\"noopener noreferrer\">NTA 8133+A1<\/a> is a standardised fire-extinguishing test for portable extinguishers intended for lithium-ion battery fires. Kiwa describes its focus as stopping combustion in limited-capacity batteries, up to 600 Wh, using extinguishers with a maximum capacity of 9 litres. In its described setup, cells hang in a metal frame rather than being fully submerged. The test is relevant to a portable extinguisher claim. It is not a test of an installed battery-room system.<\/p>\n<p>The HydroGel BM 048 data sheet lists handheld extinguishers in 2-, 6- and 9-litre sizes and specifies the 9-litre extinguisher in its NTA 8133 notation. That result applies to the tested extinguisher and test scope. It is not approval for every model, battery size or vessel, and it should not be read as marine installation approval. Verify whether a certificate has been granted, is pending or is still in progress before relying on it.<\/p>\n<p>Keep the regulatory categories distinct. Battery-product standards, dangerous-goods transport rules, portable-extinguisher tests, flag-state requirements, class rules and marine equipment approvals each cover different questions. The <a href=\"https:\/\/www.imo.org\/en\/ourwork\/safety\/pages\/faqsrelatedtofireprotection-default.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">International Maritime Organization<\/a> does not approve individual marine products. Relevant national maritime administrations generally issue approvals based on tests by recognised laboratories.<\/p>\n<h2>Does the 40\u201380 rule prevent thermal runaway?<\/h2>\n<p>No. A moderate charge range is battery-life guidance, not a guaranteed thermal runaway prevention threshold. <a href=\"https:\/\/support.microsoft.com\/en-us\/windows\/experience\/power-battery\/caring-for-your-battery-in-windows\" target=\"_blank\" rel=\"noopener noreferrer\">Microsoft recommends<\/a> roughly 20%\u201380% where possible to slow degradation during routine use, and around 40%\u201360% for a device placed in long-term storage.<\/p>\n<p>Those ranges can inform how portable devices are used or stored onboard. They do not replace the cell protections, battery management and fire-response provisions specified for an onboard battery installation.<\/p>\n<h2>Flame suppression is not proof of cell stability<\/h2>\n<p>Like charge guidance, a portable-extinguisher test cannot establish whether an onboard battery installation is adequately protected. Thermal runaway can continue within affected cells after flames disappear. An onboard response therefore depends on cooling, containment and continued monitoring as distinct safeguards. Hydrogel can be considered for the cooling and initial suppression role, subject to the installation&#8217;s conditions and the intended application.<\/p>\n<p>For a review of the vessel&#8217;s battery arrangement and proposed Hydrogel application:<\/p>\n<p><strong>Discuss an onboard application<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A lithium-ion battery fire onboard can remain hazardous after the  [&#8230;]<\/p>\n","protected":false},"author":4,"featured_media":0,"template":"","categories":[1],"tags":[],"class_list":["post-4831","blog","type-blog","status-publish","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is thermal runaway and can it be stopped onboard? - Anogas<\/title>\n<meta name=\"description\" content=\"Learn how lithium-ion thermal runaway develops onboard, what suppression can control, and why cooling, containment and monitoring still matter after flames disappear.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is thermal runaway and can it be stopped onboard? - Anogas\" \/>\n<meta property=\"og:description\" content=\"Learn how lithium-ion thermal runaway develops onboard, what suppression can control, and why cooling, containment and monitoring still matter after flames disappear.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/\" \/>\n<meta property=\"og:site_name\" content=\"Anogas\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/\"},\"author\":{\"name\":\"Harry Verbakel\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#\\\/schema\\\/person\\\/dd067f7cd26fdfc65eac33d6bedaa6b3\"},\"headline\":\"What is thermal runaway and can it be stopped onboard?\",\"datePublished\":\"2026-11-21T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/\"},\"wordCount\":1548,\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"nl-NL\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/\",\"url\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/\",\"name\":\"What is thermal runaway and can it be stopped onboard? - Anogas\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#website\"},\"datePublished\":\"2026-11-21T07:00:00+00:00\",\"description\":\"Learn how lithium-ion thermal runaway develops onboard, what suppression can control, and why cooling, containment and monitoring still matter after flames disappear.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/anogas.com\\\/nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blogs\",\"item\":\"https:\\\/\\\/anogas.com\\\/nl\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What is thermal runaway and can it be stopped onboard?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/anogas.com\\\/nl\\\/\",\"name\":\"Anogas\",\"description\":\"Anogas Hydrogel: the different fire-extinguishing\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/anogas.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/anogas.com\\\/nl\\\/#\\\/schema\\\/person\\\/dd067f7cd26fdfc65eac33d6bedaa6b3\",\"name\":\"Harry Verbakel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g\",\"caption\":\"Harry Verbakel\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is thermal runaway and can it be stopped onboard? - Anogas","description":"Learn how lithium-ion thermal runaway develops onboard, what suppression can control, and why cooling, containment and monitoring still matter after flames disappear.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/","og_locale":"nl_NL","og_type":"article","og_title":"What is thermal runaway and can it be stopped onboard? - Anogas","og_description":"Learn how lithium-ion thermal runaway develops onboard, what suppression can control, and why cooling, containment and monitoring still matter after flames disappear.","og_url":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/","og_site_name":"Anogas","twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"8 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/#article","isPartOf":{"@id":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/"},"author":{"name":"Harry Verbakel","@id":"https:\/\/anogas.com\/nl\/#\/schema\/person\/dd067f7cd26fdfc65eac33d6bedaa6b3"},"headline":"What is thermal runaway and can it be stopped onboard?","datePublished":"2026-11-21T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/"},"wordCount":1548,"articleSection":["Uncategorized"],"inLanguage":"nl-NL"},{"@type":"WebPage","@id":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/","url":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/","name":"What is thermal runaway and can it be stopped onboard? - Anogas","isPartOf":{"@id":"https:\/\/anogas.com\/nl\/#website"},"datePublished":"2026-11-21T07:00:00+00:00","description":"Learn how lithium-ion thermal runaway develops onboard, what suppression can control, and why cooling, containment and monitoring still matter after flames disappear.","breadcrumb":{"@id":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/anogas.com\/nl\/blog\/what-is-thermal-runaway-and-can-it-be-stopped-onboard\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/anogas.com\/nl\/"},{"@type":"ListItem","position":2,"name":"Blogs","item":"https:\/\/anogas.com\/nl\/blog\/"},{"@type":"ListItem","position":3,"name":"What is thermal runaway and can it be stopped onboard?"}]},{"@type":"WebSite","@id":"https:\/\/anogas.com\/nl\/#website","url":"https:\/\/anogas.com\/nl\/","name":"Anogas","description":"Anogas Hydrogel: the different fire-extinguishing","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/anogas.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Person","@id":"https:\/\/anogas.com\/nl\/#\/schema\/person\/dd067f7cd26fdfc65eac33d6bedaa6b3","name":"Harry Verbakel","image":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/secure.gravatar.com\/avatar\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/806db39383931616a04cbc499efda4f09247d7614fe0f98f588884828b3c9c33?s=96&d=mm&r=g","caption":"Harry Verbakel"}}]}},"_links":{"self":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog\/4831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/types\/blog"}],"author":[{"embeddable":true,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/users\/4"}],"version-history":[{"count":3,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog\/4831\/revisions"}],"predecessor-version":[{"id":5201,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/blog\/4831\/revisions\/5201"}],"wp:attachment":[{"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/media?parent=4831"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/categories?post=4831"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/anogas.com\/nl\/wp-json\/wp\/v2\/tags?post=4831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}