Hydrogel is a water-based extinguishing agent designed for lithium-ion battery fires. Unlike water alone, CO₂, or dry powder, it combines sustained cooling, thermal insulation between cells, and gas suppression. These properties address thermal runaway, not just visible flames. How well it performs depends on access to the battery, battery configuration, and how the agent is delivered. The sections below answer common questions about lithium-ion battery fire suppression, from why these fires behave so differently to which agents suit indoor use.
Why are lithium-ion battery fires so difficult to extinguish?
Lithium-ion battery fires are difficult to extinguish because the energy driving them comes from chemical reactions inside the battery cells, not from an external fuel source. Once thermal runaway begins, the battery generates its own heat and releases flammable and toxic gases. It can keep burning, or reignite, after visible flames appear to be out. Suppressing the flame does not necessarily stabilise the battery.
When a lithium-ion cell is mechanically damaged, overcharged, or overheated, its internal materials begin to decompose. Cell temperature rises rapidly, internal pressure builds, and the casing can rupture. Heat from one failing cell then transfers to neighbouring cells and can trigger a cascade of failures across the pack. Extinguishing one cell does not end the incident.
The gases released during thermal runaway add to the danger. Hydrogen and methane increase flammability and explosion risk, while hydrogen fluoride is corrosive and toxic. These gases can continue to be produced after flames are suppressed, so the hazard persists after the scene appears controlled. Any effective lithium-ion battery fire suppression strategy must address gas release, heat propagation, and reignition risk together, not just the initial flame.
What extinguishing agents are used on lithium-ion battery fires?
The agents most commonly used on lithium-ion battery fires are water, CO₂, dry powder, aqueous film-forming foam (AFFF), and newer purpose-built agents such as hydrogel. Each works differently and has limits. Which one is appropriate depends on the battery configuration, the environment, and how the agent can be delivered.
Water provides strong cooling and is widely available. However, it runs off hot surfaces quickly, can struggle to reach the inside of a battery pack, and can create electrical hazards if applied incorrectly. CO₂ displaces oxygen and can knock down flames, but it provides no sustained cooling, so reignition is possible once the gas disperses. Dry powder can interrupt combustion chemistry and suppress flames, but it leaves a residue and provides little cooling. AFFF has historically been used in some battery applications, but it contains PFAS compounds that are now subject to tightening restrictions across Europe and other major markets.
Purpose-built agents such as Hydrogel by Anogas are designed for the way lithium-ion battery fires behave. Hydrogel is a water-based agent containing modified natural clay. It is intended to combine sustained cooling, physical insulation, and gas suppression in one agent. This reflects the fact that battery incidents call for a different response from conventional fires, and that the agent is only one part of the overall firefighting setup.
How does hydrogel suppress lithium-ion battery fires differently from water?
Hydrogel is designed to stay in contact with hot battery surfaces, whereas water tends to run off. This sustained contact extracts more heat over a longer period. Water provides strong initial cooling, but it struggles to remain on hot vertical or irregular surfaces, which limits its effect on persistent thermal activity in a battery pack.
The key difference is hydrogel’s heat-responsive viscosity. At ambient temperature it behaves as a low-viscosity liquid that can be applied through water-based equipment. On contact with hot surfaces it thickens and adheres, forming a cooling layer that is intended to stay in place rather than drain away. Longer contact means more heat is removed, which helps reduce the risk of reignition.
Beyond cooling, how hydrogel works on a battery fire involves further mechanisms that plain water does not provide:
- Thermal isolation: The gel forms a physical barrier around affected cells. This can limit heat transfer to neighbouring cells and slow the propagation cascade.
- Gas suppression: Hydrogel can reduce concentrations of flammable gases such as hydrogen and methane and restrict oxygen availability. It also interacts with hydrogen fluoride, converting it into less harmful ionic compounds.
- Lithium-ion stabilisation: Modified clay particles in the gel are designed to bind reactive lithium ions where the agent can reach them, reducing the chemical reactivity that sustains thermal runaway.
- Reduced reignition risk: Sustained cooling, insulation, reduced oxygen availability, and chemical stabilisation together lower the likelihood of reignition. They do not guarantee it.
Reach matters. An externally applied agent may not penetrate an enclosed pack or stop every internal reaction. Performance depends on access to the cells, enclosure design, agent quantity, and discharge arrangement.
Anogas also offers Hydrogel Shield for longer-term containment, intended to help prevent reignition of damaged or extinguished batteries. This is a separate role from Hydrogel, which provides cooling and initial fire suppression.
Are CO₂ and dry powder effective on lithium-ion battery fires?
CO₂ and dry powder are not suitable as primary agents for lithium-ion battery fires. Both can suppress visible flames, but neither provides sustained cooling or addresses the thermal runaway process inside the battery. Reignition is likely once the agent disperses or settles.
CO₂ displaces oxygen around the fire and can extinguish flames quickly. However, it has no residual cooling effect. Once it dissipates, the battery may still be at high temperature with ongoing internal reactions, so reignition is a realistic outcome. CO₂ also does not neutralise the toxic gases released from the cells.
Dry powder interrupts the combustion chain reaction and can knock back flames. However, it leaves a heavy residue and offers little cooling of the battery structure. It also cannot address the internal chemistry driving thermal runaway, which makes it poorly suited to enclosed battery systems.
Both agents can have a role in an initial response to buy time. Relying on them as the primary suppression solution in facilities with battery systems, such as warehouses, EV charging infrastructure, and energy storage installations, creates significant reignition risk. A cooling-based agent capable of sustained surface contact is needed to bring the incident under control.
What makes a fire extinguisher PFAS-free, and why does it matter for battery fires?
A PFAS-free fire extinguisher contains no added per- and polyfluoroalkyl substances. These synthetic chemicals have historically been used in foam-based agents such as AFFF to improve suppression performance. PFAS persist in the environment and in the human body, and they are subject to growing regulatory restrictions. This is relevant to battery fires because incidents often occur in enclosed spaces where exposure risk is high, and because large volumes of agent can produce significant contaminated runoff.
PFAS have been widely used in firefighting foams because they reduce surface tension and help agents spread across fuel surfaces. However, they do not break down naturally, they accumulate in living organisms, and they are associated with health risks. Across Europe in particular, restrictions on PFAS in firefighting agents are tightening, which makes PFAS-containing products an increasing liability for distributors and end users.
For lithium-ion battery fires, the case for a PFAS-free fire extinguisher rests on two points. Battery incidents frequently occur indoors, in warehouses, residential buildings, recycling facilities, and vehicle charging areas, where exposure of occupants and responders is a direct concern. The volume of agent needed for a large battery fire can also be substantial, so the environmental impact of PFAS-containing runoff is significant.
Independent analysis of Hydrogel found PFAS at less than 1 ppb, which indicates no detectable PFAS at the method’s limit rather than proof of absolute absence. Hydrogel is classified as non-dangerous for humans and the environment under European chemical legislation, and it is composed of more than 99% natural components, primarily water and modified natural clay. PFAS-free status is a statement about composition. It does not by itself establish firefighting performance or any marine or equipment approval, which should be assessed separately.
Which extinguishing agent is safest for indoor lithium-ion battery fires?
No single agent is safest in every indoor situation, but Hydrogel has several properties that suit indoor use. It is PFAS-free, classified as non-dangerous for humans and the environment under European chemical legislation, and adds no toxic combustion byproducts of its own. By contrast, CO₂ displaces oxygen and creates an asphyxiation risk in enclosed spaces, and dry powder can impair visibility and breathing.
Indoor battery fires combine several risks: toxic gas release in an enclosed space, limited ventilation, proximity to people, and the potential for rapid spread to adjacent materials. The agent must suppress the fire without adding chemical hazards to an already dangerous environment.
CO₂ is particularly problematic indoors because it depletes oxygen. Dry powder creates a dense cloud that reduces visibility and can irritate the airways. AFFF-based foams introduce PFAS contamination to the indoor environment and drainage system. Water alone lacks sustained contact and can create electrical hazards if applied incorrectly, although water-based systems remain an established option when properly designed.
Hydrogel can be used on electrical equipment up to 1,000 V with appropriate nozzle configurations. It is available in handheld fire extinguishers and can be used in fixed fire suppression systems. This makes it practical for settings ranging from homes with e-bikes and portable electronics to commercial warehouses and industrial battery storage. Before relying on it in an existing installation, verify the complete setup: access to the battery, enclosure design, agent quantity, nozzle and discharge arrangement, coverage, and compatibility. An existing sprinkler system should not be assumed to work with Hydrogel without engineering checks.
The post-fire period needs the same care. Operators should keep a safe distance and use appropriate respiratory protection during any battery fire intervention, because hydrogel reduces but does not eliminate hazardous gas exposure. A fire can be considered stabilised when visible flames are absent, no new flame eruptions occur, and audible gas emissions such as hissing have stopped. Even then, residual heat and gas release can persist. Continue monitoring, restrict access, and do not treat extinguishment as proof that the battery is safe to reuse, store, transport, or dispose of.
Gerelateerde artikelen
- What is thermal runaway and can it be stopped onboard?
- What are PFAS chemicals and why are they dangerous?
- Why PFAS-Free Fire Suppression Matters for Fire Safety Professionals
- What Makes Hydrogel Suitable for Electric Vehicle Fire Suppression
- What PFAS-Free Fire Suppressant Means for Fire Safety at Home