PFAS chemicals are a large group of synthetic substances that do not break down naturally in the environment or the human body. They are hazardous because they accumulate over time, have been linked to a range of serious health conditions, and persist in soil, water, and living organisms for decades or longer. The fire safety industry is one of the sectors most heavily implicated in PFAS contamination, so this is a pressing concern for anyone involved in fire suppression. The sections below answer the most common questions about PFAS dangers, regulations, and alternatives.
How do PFAS chemicals end up in the human body?
PFAS chemicals enter the human body mainly through contaminated drinking water, food, and direct contact with PFAS-containing products. These substances are water-soluble and highly stable. They travel easily through groundwater into public water supplies, accumulate in crops irrigated with contaminated water, and migrate from food packaging into the food itself. Once ingested, PFAS compounds are absorbed into the bloodstream and distributed to organs and tissues, where they remain.
The routes of exposure are broad and often invisible to the people affected. Communities living near industrial sites, military bases, or airports where PFAS-containing firefighting foams have been used are among the most exposed. Firefighters face particularly high occupational exposure, both through contaminated foam agents and through PFAS-treated protective gear. Household products such as non-stick cookware, water-repellent clothing, and stain-resistant carpets can also release PFAS into the air and onto surfaces. This creates a low-level but persistent exposure pathway in everyday environments.
PFAS do not metabolise efficiently, so each new exposure adds to the existing body burden rather than replacing it. This cumulative effect is why even low-level, repeated exposure is a legitimate concern over a lifetime.
What health effects are linked to PFAS exposure?
PFAS exposure has been associated with a range of serious health effects. These include disruption of the immune and endocrine systems, elevated cholesterol levels, reduced vaccine effectiveness, thyroid disease, kidney and testicular cancer, and complications during pregnancy. The associations come from decades of epidemiological research and occupational health studies, particularly of populations with high exposure through contaminated water or workplace contact.
The immune system effects are among the most consistently documented findings. Research suggests that PFAS can reduce the body’s ability to mount an effective immune response. This affects both disease resistance and vaccine efficacy, particularly in children. Hormonal disruption is another well-established concern, as PFAS compounds can interfere with the body’s natural hormone signalling, affecting thyroid function and reproductive health.
Developmental effects are also a significant concern. Prenatal exposure through the placenta and postnatal exposure through breast milk mean that infants and young children can accumulate PFAS before they can make any choices about their own exposure. Some studies have linked early PFAS exposure to altered growth patterns, behavioural development, and immune function in children.
PFAS is not a single substance but a family of thousands of individual compounds, and their toxicity profiles vary. However, the most studied members of the group, including PFOA and PFOS, have generated enough evidence for regulatory agencies in Europe and North America to classify them as substances of very high concern.
Why are PFAS called ‘forever chemicals’?
PFAS are called forever chemicals because the carbon-fluorine bonds that form their molecular backbone are among the strongest in organic chemistry. These bonds resist breakdown by heat, water, sunlight, and biological processes, so PFAS compounds do not degrade in any meaningful timeframe under natural conditions. Once released, they persist, cycling through soil, groundwater, surface water, and living organisms without disappearing.
This persistence has a direct consequence for contamination: there is no natural recovery process. A site contaminated by firefighting foam applied decades ago still carries measurable concentrations today. Those concentrations will remain until active remediation is carried out. Groundwater contamination is particularly difficult to address because PFAS travel with water movement, spreading contamination far beyond the original release point.
The same persistence applies inside the human body. The biological half-life of some PFAS compounds, which is the time the body takes to eliminate half of the accumulated amount, is measured in years rather than days or weeks. This is why body burden increases with repeated exposure. It is also why PFAS can be detected in blood samples from people who have had no obvious or direct contact with PFAS-containing products.
Where are PFAS most commonly found in fire safety products?
PFAS are most commonly found in fire safety products through aqueous film-forming foam, widely known as AFFF. For several decades, AFFF has been the dominant suppression agent for flammable liquid fires, particularly in aviation, military, and industrial settings. The PFAS compounds in AFFF create a thin film that spreads rapidly across fuel surfaces, cutting off oxygen and suppressing vapour release. This made AFFF highly effective, but at a significant environmental cost.
PFAS have also been used in firefighter protective clothing and equipment, where fluorinated treatments provide water and chemical resistance. Some foam concentrates used in fixed suppression systems and portable extinguishers have historically contained PFAS as a functional ingredient. As a result, fire safety operations, training exercises, and equipment maintenance have been a significant source of PFAS contamination in soil and groundwater around fire stations, airfields, and industrial facilities worldwide.
The sector’s reliance on PFAS-containing agents reflects the genuine performance advantages these substances provided. Replacing them requires alternatives that can match suppression effectiveness without the environmental and health liabilities. Anogas Hydrogel is one such approach. It is a water-based agent containing modified natural clay, and it contains no PFAS. Its chemistry differs fundamentally from foam-based fire suppression chemistry. PFAS-free status describes the composition only. Suppression performance for a given application still needs to be verified separately.
What regulations exist to limit PFAS use?
Regulatory action on PFAS is accelerating across Europe and North America. In the European Union, Regulation (EU) 2025/1988 is phasing out PFAS-containing extinguishing agents, with a complete ban expected by 2031. The regulation reflects the EU’s broader PFAS restriction strategy under the REACH chemical safety framework. That strategy aims to address the class of substances as a group rather than restricting individual compounds one at a time.
This marks a significant shift from earlier efforts, which targeted specific compounds such as PFOS and PFOA individually. The group-based approach is more comprehensive and closes loopholes that allowed manufacturers to substitute one PFAS compound for another. For fire safety operators, distributors, and equipment manufacturers, products containing any PFAS will face market restrictions, regardless of which compound is involved.
Regulatory pressure is also building in other jurisdictions. Several countries have introduced drinking water limits for PFAS, and occupational exposure standards for firefighters are being reviewed in light of accumulating health evidence. In some regions, liability for PFAS contamination from firefighting operations is already being tested in the courts, which adds a financial dimension to the compliance argument.
For businesses in the fire safety supply chain, the practical implication is clear: products that rely on PFAS-containing agents face a shrinking regulatory window. Organisations should assess which of their products and agents contain PFAS, confirm the applicable deadlines in their jurisdictions, and plan the transition early. Moving to PFAS-free alternatives before mandatory dates puts them ahead of compliance requirements and reduces long-term liability.
What are the alternatives to PFAS in fire suppression?
The main alternatives to PFAS in fire suppression include fluorine-free foams, compressed air foam systems using non-fluorinated concentrates, water mist systems, and newer agent technologies based on mineral or polymer chemistry. The right choice depends on the fire class, the application environment, and the performance requirements of the installation.
Fluorine-free foams have been developed to replicate some of the film-forming behaviour of AFFF without fluorinated surfactants. These products have improved significantly in recent years and are approved for a growing number of applications. However, their performance on some high-intensity flammable liquid fires can still differ from AFFF. They are also not designed for the specific challenges of lithium-ion battery fires.
Lithium-ion battery fires are a distinct suppression challenge. The energy driving the incident comes from chemical reactions inside the battery cells, not from a conventional fuel source. Extinguishing visible flames does not necessarily end internal heating, gas release, or thermal runaway, so reignition remains a risk. Water, dry chemical, CO2, and foam can each control flames or remove heat to different degrees. Their limitations differ, and the right choice depends on the battery configuration and how the agent can be delivered.
Hydrogel, developed by Anogas, is a water-based agent containing modified natural clay. It cools hot surfaces, and its viscosity increases with heat. This is intended to keep the agent in contact with hot surfaces rather than running off. Its effect depends on whether the agent can reach the affected cells. An externally applied agent may not penetrate an enclosed battery pack or stop every internal reaction. Performance therefore depends on battery configuration, agent delivery, and the available test evidence. Hydrogel is positioned for cooling and initial fire suppression. Longer-term containment to help prevent reignition is the role of a separate product, Hydrogel Shield.
When evaluating a PFAS-free fire extinguisher for lithium-ion battery risks, verify the specific model and the test it passed, and confirm the scope and limits of any certification. Also check access to the battery, enclosure design, agent quantity, and discharge arrangement. After the fire, allow for residual heat, gas hazards, and monitoring. Extinguishment does not mean the battery is safe to reuse, store, transport, or dispose of.
The transition away from PFAS is not only a compliance exercise. It is an opportunity to adopt suppression technologies that are safer for operators, less damaging to the environment, and better suited to the fire risks that modern energy systems create. Understanding what PFAS chemicals are and why they are dangerous is the first step towards informed decisions about the fire safety products used in any facility or fleet.
Gerelateerde artikelen
- What is the difference between Hydrogel and traditional marine extinguishers?
- How Hydrogel Reduces the Risk of Re-Ignition After Battery Fires
- Why Lithium-Ion Battery Fires Are a Growing Safety Risk
- Understanding Hydrogel Fire Suppression for Industrial Environments
- How Hydrogel Effectively Extinguishes Lithium-Ion Battery Fires


