Hydrogel is designed to help control lithium-ion battery fires. It is a water-based agent containing modified natural clay, and it becomes more viscous on contact with hot surfaces, so it stays in contact with the battery and keeps cooling it. Water runs off hot surfaces quickly. Hydrogel is intended to stay in place long enough to cool the battery and slow the thermal runaway cycle that makes these fires so persistent. How well it performs depends on whether the agent can reach the affected cells.
As electric vehicles, e-bikes, energy storage systems, and portable electronics become more widespread in 2026, lithium-ion battery fires are a growing fire safety challenge in homes, warehouses, industrial facilities, and public spaces. The sections below cover how Hydrogel works against these fires, how it compares with conventional agents, what it cannot do on its own, and where else it can be used.
Why are lithium-ion battery fires so difficult to extinguish?
Lithium-ion battery fires are difficult to extinguish because of thermal runaway, a self-sustaining chemical process. When a cell overheats, through damage, overcharging, or a manufacturing defect, it releases energy that heats adjacent cells. This triggers a chain reaction that generates heat, flammable gas, and in some chemistries its own oxygen internally. The fire can therefore continue without external oxygen, and it can reignite hours after it appears to be out.
Extinguishing visible flames is not the same as stabilising the battery. Internal heating, gas release, and the risk of reignition can continue after the flames are out. Conventional agents struggle for two main reasons:
- They may not cool the cells deeply or quickly enough to break the thermal runaway chain before it spreads to neighbouring cells.
- Agents that run off hot surfaces, including plain water, may not stay in contact with the heat source long enough to prevent temperatures from rebounding.
Access is also a problem. Cells are packed tightly inside modules and enclosures, which limits what an externally applied agent can reach. Responders may need to monitor a battery fire scene for many hours after initial suppression. In enclosed spaces such as parking garages or cargo holds, repeated ignition is a serious risk.
How does Hydrogel suppress lithium-ion battery fires?
Hydrogel combines cooling with heat-responsive viscosity. At ambient temperatures it is a low-viscosity, water-based fluid that can be applied through standard nozzles. On contact with a hot battery surface, it thickens into a gel that adheres to the surface. The gel stays in contact with the hot surface, so cooling continues instead of ending when the agent runs off.
The gel-forming mechanism is what sets Hydrogel apart from water in this context. Water makes only brief contact before running off. The modified natural clay in the gel also acts as a barrier against oxygen and flammable gases, which adds a suppression layer to the primary cooling effect.
The goal is not only to knock down visible flames but to bring surface temperatures down and keep them down. Hydrogel acts on what the agent can reach. It cannot be assumed to cool cells inside a sealed pack or to stop every internal reaction. Performance depends on access to the battery, the battery configuration, how the agent is delivered, and the available test evidence.
What makes Hydrogel more effective than water for battery fires?
Water cools well and is widely available, and it remains a valid option for many battery fires, particularly where large volumes can be applied. Its limitation is that it runs off hot surfaces quickly, and what remains evaporates or drains away. Hydrogel forms a persistent gel layer on contact with heat, so cooling is maintained on the battery surface over a longer period.
This has practical consequences beyond suppression speed:
- Less agent may be needed to achieve the same cooling effect, which can reduce the volume of contaminated runoff. This matters because runoff from lithium-ion battery fires can carry toxic compounds into drainage systems.
- Smaller extinguisher units may be able to deliver equivalent performance in some applications. Verify this against the specific extinguisher model and test evidence.
- Hydrogel is over 95% water, but it can be used on electrical equipment up to 1,000 V when applied with suitable nozzle configurations. Water alone carries significant conductivity risks in these situations. Confirm the nozzle arrangement and operating limits before relying on this.
Can Hydrogel prevent thermal runaway reignition?
Hydrogel is intended to help reduce the risk of reignition. It is not a guarantee. Its sustained adhesion keeps surface temperatures suppressed after initial extinguishment, which narrows the window in which residual heat can trigger a secondary ignition. The clay in the gel can also limit the escape of flammable gases from the surface it covers.
Reignition is one of the most dangerous characteristics of lithium-ion battery fires. A module can appear extinguished while internal cell temperatures remain high enough to restart thermal runaway, sometimes hours later. Agents that evaporate or drain away quickly leave the surface unprotected during this period. Hydrogel’s thermal runaway blocking properties address this by maintaining a physical and thermal barrier on the exposed battery surface after initial suppression.
Hydrogel cannot be assumed to reach enclosed cells or eliminate battery gases. For damaged or extinguished batteries that need longer-term containment, Hydrogel Shield is the product intended to help prevent reignition. Hydrogel itself is for cooling and initial fire suppression.
Whichever product is used, treat the post-fire period as part of the response. Plan for residual heat, gas hazards, restricted access, and continued monitoring. Do not treat extinguishment as confirmation that the battery is safe to reuse, store, transport, or dispose of. In facilities with high reignition risk, such as recycling plants handling electronic waste, maritime cargo holds, or large energy storage installations, assess these points before deciding on an agent.
What fire types can Hydrogel extinguish besides battery fires?
Hydrogel is rated for Class A, B, and F fires:
- Class A: solid combustible materials such as wood, paper, and textiles.
- Class B: flammable liquids and non-polar fuels.
- Class F: cooking oils and fats, a common cause of serious domestic and commercial kitchen fires.
This coverage comes from a dual-action mechanism. The water content cools the burning material. The clay content floats on non-polar fuels and fats, forming a suppression barrier. On solid fires, the gel adheres to vertical surfaces, including walls and ceilings, which water cannot do effectively.
A single Hydrogel fire extinguisher can therefore cover most of the fire types found in warehouses, industrial facilities, maritime environments, and recycling operations. This can reduce the number of agent types to stock, train for, and maintain. Confirm the rating and scope of the specific extinguisher model against the risks on site.
Is Hydrogel safe for the environment after a battery fire?
Hydrogel contains no intentionally added PFAS. Analytical testing found less than 1 part per billion of PFAS, which is a non-detection result rather than proof of absolute absence. It consists of more than 99% naturally derived components, primarily modified natural clay and water. Aquatic toxicity studies conducted according to OECD Guidelines for Testing of Chemicals found it non-toxic to algae and daphnia, two standard environmental indicators.
This is relevant when comparing agents. Many foam-based agents contain PFAS compounds, which persist in the environment and are linked to serious health and ecological concerns. This is driving regulatory phase-outs across Europe and other markets. A PFAS-free agent does not add these pollutants to the runoff from a suppression event.
PFAS-free status does not by itself establish overall safety, firefighting effectiveness, or marine approval. Runoff from a battery fire can still contain contaminants from the battery. These should be assessed and managed separately.
Hydrogel has a service life of more than 10 years and can be discharged at the end of that life without environmental risk. After its full service period, it is expected to be recyclable into a compost-enrichment supplement, which is the basis of what Anogas describes as a fully circular fire extinguisher product. For facilities with strict environmental compliance requirements or sustainability commitments, this lifecycle profile supports the case for a PFAS-free extinguishing agent. Weigh it alongside performance evidence, the complete firefighting setup, and any approvals the application requires.