What is the difference between Hydrogel and traditional marine extinguishers?

Lithium-ion battery fires aboard vessels can escalate in confined spaces and release toxic and flammable gases, complicating crew response. A Hydrogel marine extinguisher differs from conventional equipment through heat-responsive adhesion: water cools the hot surface while the modified natural clay is intended to form a barrier to oxygen and flammable gases. That makes Hydrogel a potential addition to battery-fire protection, not a replacement for required, approved marine extinguishers.

What type of fire extinguisher is best for boats?

For a U.S. recreational boat required to carry an extinguisher, the starting point is a serviceable unit with the applicable B rating and a “Marine Type – USCG Approved” label. The USCG explains that Underwriters Laboratories approves boat extinguishers on its behalf; BoatUS identifies 5-B, 10-B and 20-B as the relevant portable-extinguisher labels. The boat’s fuel, galley and battery hazards then inform any additional protection.

Anogas sells handheld Hydrogel extinguishers under the ASAPs name for solids, fats and lithium-ion battery fires. That product description does not establish that a particular unit has the ratings or marine approval needed to count towards U.S. carriage. The ASAPs unit is specified for use on energized equipment up to 1,000 volts from 1 metre away. That is a condition for this unit, not permission to apply water-based agents to energized equipment generally.

What are the five fire extinguisher classes used for?

In the RYA’s boat-safety guidance, the five groups identify what is burning:

  • Class A: solids such as wood, paper and textiles.
  • Class B: flammable liquids such as petrol, diesel and oil.
  • Class C: gases.
  • Class D: metals.
  • Class F: cooking oils and fats.

A class letter identifies a hazard, not every extinguisher that can handle it. The number beside a letter indicates the size of fire the unit is rated to tackle. The RYA lists water, dry powder, foam and carbon dioxide (CO₂) as common extinguishing media. Each still needs an appropriate rating for the intended fire.

The RYA treats live electrical equipment separately: once power is isolated, the burning material determines the class, although other jurisdictions may use different terminology. A fleet specification should therefore use the ratings and class definitions applicable where the vessel operates. The same letter does not necessarily mean the same hazard everywhere.

See where Hydrogel fits your fire-safety strategy
From lithium-ion batteries to existing water-based suppression systems, speak with Anogas about your application.

Discuss your application

Is a cooking-oil or grease fire a Class C fire?

No. Under the RYA’s five-class system, cooking oils and fats are Class F; Class C concerns gases. For galley protection, that distinction is more useful than an agent’s name because it directs attention to the unit’s marked suitability for the fire.

Hydrogel foam floats on fats and non-polar fuels, and the handheld units are intended for fat fires. That general description does not give every Hydrogel extinguisher a cooking-oil rating. The marking on the proposed unit remains the selection criterion.

Why is a water fire extinguisher unsuitable on a petrol fire?

A plain-water extinguisher should not be selected for petrol. Its water content does not establish suitability for a flammable-liquid fire. Petrol belongs to Class B in the RYA system, so the extinguisher needs a rating for that hazard.

Hydrogel is water-based, but its foam is designed to float on non-polar fuels. That does not confer a Class B rating on every Hydrogel unit. For a fuel space, verify the particular unit’s marked rating before including it in the protection plan.

Which is better for a boat, ABC or CO2?

Neither label alone settles the choice for a U.S. recreational boat. An ABC- or CO₂-labelled unit counts towards carriage only if that particular extinguisher meets the applicable B-rating and marine-approval requirements. Its other marked ratings then need to match the hazards it is intended to cover.

Choice What the label tells a buyer What still needs checking
ABC-labeled extinguisher The unit is marked for multiple fire groups under its applicable rating system. Its B rating, marine approval and the meaning of its class letters in the relevant jurisdiction.
CO₂ extinguisher CO₂ identifies the extinguishing medium, not a complete set of fire ratings. The particular unit’s marked hazards, B rating and marine approval.

The RYA lists CO₂ alongside water, powder and foam as a common medium, and gives 5A/34B as an example of a unit rated for two fire groups. For U.S. carriage, BoatUS points to 5-B, 10-B or 20-B labels. Those markings provide a firmer basis for procurement than an ABC-versus-CO₂ preference.

Is a 2-A or 3-A fire extinguisher better?

Within the same rating system, 3-A indicates capacity for a larger Class A fire than 2-A. The RYA’s rating explanation assigns the number to fire size and the letter to the burning material.

That gives 3-A the higher Class A rating, though it is not necessarily the better boat extinguisher. Neither A number establishes suitability for a fuel fire or U.S. carriage. The unit’s other ratings and, where required, its marine-approval label decide those questions.

How does Hydrogel differ from traditional marine extinguishers on lithium-ion battery fires?

Conventional marine extinguishers are selected by their approved ratings for defined fire hazards. Water, dry chemical, CO₂ and foam each have a role, and each has limitations. Hydrogel adds a different mechanism: it is designed to keep cooling agent in contact with a hot surface. It is a water-based agent containing modified natural clay, and the handheld agent is more than 95% water.

Its viscosity rises with temperature, so the foam is intended to adhere to hot surfaces, including vertical ones. Hydrogel stays on hot surfaces longer than water alone. For a battery hazard, that longer contact can help keep cooling at the fire source.

Suppressing visible flames does not necessarily end internal heating, gas release, thermal runaway or the risk of reignition. An externally applied agent may not reach cells inside an enclosed pack. Performance depends on access to the battery, its configuration, how the agent is delivered and the available test evidence.

Anogas lists electric and hybrid vessels, battery rooms and onboard energy storage as applications. Longer adhesion can reduce agent use and contaminated runoff, and Hydrogel contains no PFAS. Those are relevant procurement considerations, but the agent quantity and runoff for a particular installation belong in its technical assessment.

The clay barrier does not eliminate hazardous gases. Battery-fire response in a confined vessel space still has to account for toxic and flammable gas release, limited evacuation options, residual heat and monitoring after the fire. It also has to account for the vessel’s required firefighting equipment. Hydrogel’s cooling and isolation role sits within that response, not outside it.

Do automatic fire extinguishers work on boats?

An automatic system can protect a defined onboard hazard when the installed system is suitable for that space and application. Hydrogel can be foamed at a sprinkler nozzle by mixing it with air, whereas a mobile extinguisher uses propellant gas instead. These are different delivery arrangements, not interchangeable equipment decisions.

Hydrogel is described as compatible and interchangeable with water in water-based suppression systems. Do not assume an existing sprinkler system works with Hydrogel. For a battery room, charging station or cargo installation, verify the system, nozzle arrangement, agent quantity, coverage, temperature range and applicable approvals. Engineering and approval checks should precede any modification. A portable first-response extinguisher and an installed automatic system also have different jobs.

How many fire extinguishers does the USCG require by boat length?

The number depends on the U.S. recreational boat’s applicable length-based carriage requirement. The USCG’s rule effective April 20, 2022, did not change which boats must carry extinguishers or how many they need. A count without the boat’s length and qualifying equipment would not answer the procurement question.

  • Establish whether carriage is required. Permanently installed fuel tanks and spaces capable of trapping fumes are relevant triggers. The USCG includes closed compartments beneath seats that may hold portable fuel tanks, closed living spaces and certain closed stowage spaces.
  • Check the quantity for the boat’s length. Use the USCG carriage guidance for the vessel rather than assuming a battery-focused addition changes the required count.
  • Check each unit being counted. Confirm its marine-approval label and applicable B rating. BoatUS notes an allowance for serviceable B-I and B-II units on boats from model years 1953–2017; those older labels alone do not satisfy newer labelling requirements.
  • Confirm serviceability. The USCG treats a disposable, non-rechargeable unit with a UL trademark and stamped manufacture date as expired when more than 12 years old. BoatUS also identifies an operable indicator, seated lock pin, clear nozzle and no significant visible corrosion or damage as checks.

The pressure gauge on an ASAPs unit can be read without dismantling it. Ease of inspection is useful, but it does not establish that the unit qualifies for the required count.

Hydrogel is an addition to rated marine protection

Hydrogel’s heat-responsive adhesion, sustained cooling and clay barrier distinguish it from selecting a conventional extinguisher solely by fire-class rating. For a vessel with lithium-ion battery hazards, that makes it a potential battery-focused addition. It does not replace the obligation to carry the approved, rated and serviceable marine extinguishers the vessel requires.

Test results and certifications need the same scrutiny as ratings. Identify the specific extinguisher model, test and scope. A portable-extinguisher test is not approval of a complete marine battery installation, and a pending certificate is not a granted one.


For a particular battery space or existing water-based system, review the agent and maritime applications alongside the proposed unit’s documentation.

Review Hydrogel · Explore maritime applications