A water-based fire suppressant can work on certain electrical fires, but only when it is formulated and applied correctly. Standard water carries electrical current and poses a serious shock hazard. Advanced water-based agents such as hydrogel are designed to manage heat, limit flame spread and reduce reignition risk, including in electrically energised environments. The sections below answer the questions that fire safety professionals and distributors ask most often.
Can water-based agents suppress electrical fires safely?
Yes, but the formulation matters. Pure water conducts electricity and creates a direct shock risk on live equipment. A purpose-engineered water-based fire suppressant is designed to minimise conductivity, and it must be applied through the correct nozzle configuration. Anogas Hydrogel is confirmed safe for use on electrical equipment up to 1,000 V when applied with suitable nozzle setups.
The distinction is between water as a raw agent and water as the base of a more sophisticated suppression medium. In a hydrogel system, the water provides cooling while the gel matrix controls how the agent behaves on contact with energised surfaces. The result is a water-based fire suppressant that is intended to deliver the cooling of water with less of the uncontrolled runoff that makes plain water a hazard near electrical infrastructure.
Before relying on any agent near energised equipment, verify the voltage rating, the nozzle arrangement and the safe application distance for your specific installation. A voltage rating applies only to the tested conditions. It does not replace a site-specific assessment.
How does hydrogel behave differently from water on a fire?
Hydrogel is a water-based agent containing modified natural clay. Its viscosity responds to heat. Water runs off hot surfaces almost immediately, whereas hydrogel thickens on contact with heat and is intended to stay on the fire source. The cooling agent therefore remains in contact with the burning material for longer, concentrating heat absorption where it is needed instead of draining away.
This adhesion has three practical consequences. First, less suppressant is generally needed for the same cooling effect, which can reduce contaminated runoff. Second, the gel layer forms a physical barrier that restricts oxygen and separates flammable gases from ignition sources. Third, the gel can expand during application, increasing surface coverage.
When applied as foam through a handheld extinguisher or fixed system, hydrogel also clings to vertical surfaces and ceilings. This helps in three-dimensional fire scenarios where plain water drains away. For a detailed explanation of the chemistry, see Anogas’s guide to how Hydrogel works.
Why are lithium-ion battery fires so difficult to extinguish?
The energy sustaining a lithium-ion battery fire comes from chemical reactions inside the cells, not only from external fuel. This process is called thermal runaway, and it is self-reinforcing. As one cell overheats, it releases flammable and toxic gases, raises pressure and passes heat to neighbouring cells. The failure can cascade even after visible flames have been suppressed.
Suppressing visible flames is therefore not the same as stabilising the battery. Internal heating and gas release can continue after the flames are out. Those gases include hydrogen, methane and hydrogen fluoride. Hydrogen and methane increase explosion risk, and hydrogen fluoride is toxic and corrosive. A fire that appears to be out can still create hazardous conditions and can reignite.
Conventional agents each have limits in this scenario. Water cools surfaces, but it may not reach cells inside an enclosed pack. Foams have historically relied on PFAS-based chemistry that is now being phased out by regulation. Dry powder suppresses flames but provides little sustained cooling and does not interrupt internal reactions. Each of these agents has a role in the wider fire-safety response, and the right choice depends on the application.
Hydrogel is designed to address several parts of the problem. It provides rapid, sustained cooling, which can help limit heat transfer to adjacent cells. Its gel layer is intended to reduce gas and flame spread at the surface, and its modified clay is intended to help stabilise the area it contacts. Together, these actions can help reduce the risk of reignition. Performance depends on access to the battery, battery configuration, agent delivery and available test evidence. An externally applied agent cannot be assumed to reach every cell in an enclosed pack. This is why Anogas positions Hydrogel as a thermal runaway blocker within a wider response, not a guarantee against reignition.
After a lithium-ion battery fire, treat the battery as hazardous until proven otherwise. Allow for residual heat and gas hazards, restrict access, monitor the battery and handle it safely. Extinguishment does not mean the battery is safe to reuse, store, transport or dispose of.
What fire classes can a water-based suppressant handle?
A well-formulated water-based fire suppressant can cover Class A fires involving solid materials such as wood, paper and textiles, Class B fires involving flammable liquids, and Class F fires involving cooking oils and fats. Hydrogel is certified for all three classes. Certification applies to specific extinguisher models and test conditions, so confirm the scope of the test or certificate before assuming a wider approval.
Lithium-ion battery fires do not fit neatly into the traditional classification system because of their internal energy source and thermal runaway behaviour. Handling both conventional fire classes and battery-related incidents with one agent is a practical advantage where several risks coexist. It does not make a single agent the right answer to every scenario.
This breadth is relevant to warehousing and logistics, recycling centres handling electronic waste, maritime environments and any site where EV charging or energy storage sits alongside conventional combustible materials. A single suppressant can simplify procurement, training and maintenance, provided the complete firefighting setup has been assessed.
What does PFAS-free mean for a fire suppressant?
A PFAS-free fire suppressant contains none of the per- and polyfluoroalkyl substances widely used in firefighting foams, particularly aqueous film-forming foam. PFAS are highly persistent synthetic chemicals. They do not break down naturally, and they accumulate in soil, contaminate groundwater and build up in living organisms. This is why they face growing restriction and bans in many jurisdictions.
For fire safety professionals and distributors, PFAS-free status is now a compliance consideration, not only a marketing preference. Regulation (EU) 2025/1988 is phasing out PFAS-containing extinguishing agents, with a complete ban expected by 2031. Organisations that continue to rely on PFAS-based suppressants face product obsolescence, regulatory exposure and growing liability.
Hydrogel is formulated without PFAS. Analytical testing found PFAS at less than one part per billion, which is the practical limit of detection. A result below the detection limit shows non-detection, not proof of absolute absence. PFAS-free status is also a statement about chemical composition. It does not on its own establish environmental harmlessness, firefighting performance or marine approval, and each of these must be assessed separately. Hydrogel is made of modified natural clay and water, and after a service life of more than ten years it is expected to be recyclable as a compost-enrichment supplement.
For distributors building a portfolio for long-term regulatory compliance, a PFAS-free fire extinguisher based on hydrogel technology is a defensible choice. Confirm the certification status of the specific model before specifying it.
How does a water-based suppressant integrate with existing fire systems?
Hydrogel is designed to be interchangeable with water in many water-based systems, including sprinkler networks, deluge systems, foam proportioning systems and handheld extinguishers. In principle, it replaces water as the working fluid in existing pipework and delivery hardware. Do not assume an existing sprinkler system works with Hydrogel automatically. Compatibility must be confirmed through an engineering assessment that considers nozzles, discharge arrangement, coverage, agent quantity and any required approvals.
Hydrogel is supplied as a ready-to-use premix that needs no dilution or on-site preparation, which removes a common source of application error. It is available in 25-litre jerrycans for smaller installations and in 300-litre and 1,000-litre intermediate bulk containers for large-scale industrial or building deployments. It should only be applied at ambient temperatures above zero degrees Celsius. Hydrogel SubZ is the frost-protected formulation for relevant cold-temperature applications.
Because less agent can be needed for equivalent cooling, existing storage and delivery capacity may support a hydrogel-based system without expansion. Any such conclusion depends on the application and should be verified. Using less agent can also reduce contaminated runoff, which matters for environmental compliance and cleanup costs.
Do not replace mandatory fire protection or modify an existing system without engineering and approval checks. For fixed installations, assess the range of fire suppression systems that can work with hydrogel technology, and select and verify the configuration against your site requirements.
Related Articles
- How does cooling capacity affect fire suppression performance?
- What is the safest fire suppression agent for the environment?
- How Water-Based Hydrogel Makes Fire Suppression More Sustainable
- How Hydrogel Controls Thermal Runaway in Lithium-Ion Batteries
- How Hydrogel Effectively Extinguishes Lithium-Ion Battery Fires