How Sustainable Fire Suppression Works with Water-Based Hydrogel

Sustainable fire suppression with water-based hydrogel replaces conventional chemical agents with a water-based agent containing modified natural clay. It is designed to cool, isolate, and stabilise fires without releasing harmful substances into the environment. Unlike foam agents containing PFAS or other hazardous chemicals, Hydrogel is derived from naturally occurring components and carries a carbon footprint of less than 0.7%. The sections below explain how the technology works, which fires it is designed for, and what fire safety professionals and distributors should verify before specifying it.

What makes water-based hydrogel different from traditional extinguishing agents?

Hydrogel combines the cooling power of water with a heat-responsive viscosity. It thickens on contact with heat, which is intended to keep the agent in contact with hot surfaces. Water and many foam agents can run off hot surfaces quickly, whereas Hydrogel adheres for longer. In suitable applications, this can mean less agent is needed to achieve the same result.

Conventional foam agents, particularly aqueous film-forming foams, have historically relied on PFAS chemistry to achieve surface adhesion and fire suppression. Hydrogel achieves adhesion through a different mechanism. Modified natural clay particles increase the agent’s viscosity as temperatures rise, so it does not simply drain away from a burning surface. It forms a cooling layer where it is applied.

The practical implication is lower agent consumption per incident, depending on the fire and the delivery method. That can reduce the cost of intervention and the volume of contaminated runoff to be managed afterwards. For industrial sites, warehouses, and maritime operators, less secondary contamination is a meaningful operational advantage. Other agents, including water, dry chemical, CO2, and foam, remain effective in the applications they were designed for.

You can explore the technical detail behind this mechanism on the how hydrogel works page.

See where Hydrogel fits your fire-safety strategy
From lithium-ion batteries to existing water-based suppression systems, speak with Anogas about your application.

Discuss your application

How does hydrogel extinguish lithium-ion battery fires?

Hydrogel addresses lithium-ion battery fires through cooling, thermal isolation, and a degree of gas and chemical stabilisation. It is designed to suppress flames and reduce heat at the point of application. Extinguishing visible flames does not necessarily end internal heating, gas release, or thermal runaway, and a battery can reignite after the flames are out. The wider response therefore has to cover the period after the fire as well.

Cooling and thermal containment

The high water content of Hydrogel absorbs heat and lowers battery temperature. As temperature rises, the gel thickens and adheres to battery surfaces, forming an insulating layer that can limit heat transfer to adjacent cells. This is intended to slow thermal propagation, where heat from one failing cell triggers failure in neighbouring cells. The gel can also expand during application, which can improve contact with irregular battery surfaces.

Reach matters. An externally applied agent does not necessarily reach cells inside an enclosed pack or stop every internal reaction. Performance depends on access to the battery, pack configuration, enclosure design, and how the agent is delivered.

Gas suppression and lithium stabilisation

Lithium-ion battery fires can release hazardous gases, including hydrogen, methane, and hydrogen fluoride. Hydrogel can help reduce concentrations of flammable gases and restrict oxygen availability. It can also interact with hydrogen fluoride, converting it into less harmful ionic components. Where modified clay particles reach damaged battery structures, they may bind reactive lithium ions and contribute to stabilisation. These effects depend on how much of the agent reaches the affected cells. They do not replace ventilation, gas monitoring, or restricted access.

After a battery fire has been suppressed, continued monitoring remains essential. In the testing and guidance referenced by Anogas, an observation period of at least 20 minutes was used to detect renewed instability, followed by at least 48 hours of cooling before disposal. Treat these figures as application-specific and confirm the appropriate periods for your battery type and setting. Affected battery packs should be moved to a water-filled containment vessel or stored in a well-ventilated area, isolated from combustible materials. Do not treat extinguishment as a sign that a battery is safe to reuse, store, transport, or dispose of. Residual Hydrogel can be removed by absorbing excess material and rinsing with water. Used agent can be collected and recycled, and its clay-based components may be suitable for reuse as compost enhancers.

Different products serve different roles. Hydrogel provides cooling and initial fire suppression. Hydrogel Shield is intended for longer-term containment, to help prevent reignition of damaged or extinguished batteries. For a detailed breakdown of how the thermal runaway blocker mechanism works in practice, Anogas provides application-specific guidance covering battery systems from small consumer devices through to large industrial installations.

Is hydrogel fire suppression safe for the environment?

Hydrogel is classified as non-dangerous for humans and the environment under the most stringent European chemical legislation. It is composed of more than 99% naturally derived components. Aquatic toxicity studies conducted according to OECD testing guidelines found it to be non-toxic to algae and daphnia.

The environmental case rests on what Hydrogel contains and what it does not. It is formulated from modified natural clay and water, with a carbon footprint of less than 0.7%. It contains no PFAS or other synthetic fluorinated compounds. Analytical testing found PFAS below the detection limit, which shows that none was detected rather than proving absolute absence. PFAS-free status describes chemical composition. It is not, by itself, evidence of firefighting performance or marine approval.

End-of-life management is straightforward. Hydrogel has a service life of more than ten years, so replacement for technical reasons is not normally required. When replacement is necessary, the agent can be discharged without environmental risk. After its service life, it is expected to be recyclable into a compost-enrichment supplement, which reflects its natural clay and water composition. Check local waste and discharge requirements before disposal, particularly where the agent has been contaminated by fire residues.

Can hydrogel be used in existing water-based fire suppression systems?

Hydrogel is designed to be interchangeable with water in water-based fire suppression systems, so facilities with sprinkler, deluge, or other water-based equipment may be able to use it without replacing existing infrastructure. Compatibility still has to be confirmed for each installation. Do not assume an existing sprinkler system works with Hydrogel automatically.

Before making any change, assess the complete setup:

  • access to the hazard and enclosure design
  • agent quantity, nozzle and discharge arrangement, and coverage
  • operating temperature and material compatibility
  • the approvals required for the installation

Mandatory fire protection, particularly in marine settings, must not be replaced or modified without engineering review and the relevant approvals.

Hydrogel can also be used on electrical equipment up to 1,000 V when applied with suitable nozzle configurations, which extends its applicability to environments where electrical hazards sit alongside other fire risks. For handheld applications, portable hydrogel fire extinguishers are available where fixed suppression systems are not installed or a first-response capability is required. When reviewing test evidence, identify the specific extinguisher model, test standard (such as NTA 8133 or EN 3-11), scope, and limitations. A portable-extinguisher test is not approval of a complete marine battery installation.

What fire types can water-based hydrogel suppress?

Hydrogel is designed for Class A fires (solid materials such as wood, paper, and textiles), Class B fires (flammable liquids), and Class F fires (cooking oils and fats), as well as lithium-ion battery fires. Suitability depends on the specific product, test evidence, and application. For environments facing several fire risk categories at once, this breadth can reduce the number of agents to specify, stock, and train for.

The gel’s behaviour adapts to the fire type. On solid surfaces, it adheres to vertical walls and ceilings, maintaining a cooling layer across irregular geometries. On non-polar fuels and fats, it floats and forms a barrier between the fuel and ignition sources. For lithium-ion battery incidents, the cooling and stabilisation mechanisms described above apply, subject to the access and delivery limits already noted.

This is particularly relevant where fire risk profiles are mixed. Warehousing and logistics operations may store conventional goods alongside battery-powered equipment. Maritime vessels carry hydrocarbon fuels and increasingly large battery systems. Recycling facilities handle electronic waste, industrial waste streams, and combustible materials in close proximity. A single agent covering these risks can simplify procurement, training, and compliance. It should still be positioned within the wider fire-safety response, not as a universal solution. For cold-temperature applications, Hydrogel SubZ is the frost-protected formulation. For fixed installation contexts, hydrogel-based suppression systems are available for industrial and building fire protection applications.

See where Hydrogel fits your fire-safety strategy
From lithium-ion batteries to existing water-based suppression systems, speak with Anogas about your application.

Discuss your application

How does PFAS legislation affect fire suppression product choices?

PFAS legislation is changing which fire suppression products can be specified. Restrictions on per- and polyfluoroalkyl substances are being introduced across the European Union and in other markets, targeting foam agents that have been standard for decades. Products containing PFAS face phase-out timelines, use restrictions, and in some jurisdictions outright bans, which creates demand for compliant alternatives.

For distributors and operators, this creates both a compliance obligation and a procurement decision. Continuing to stock or specify PFAS-containing agents where restrictions are tightening introduces regulatory risk, potential liability for environmental contamination, and reputational exposure. Regulatory frameworks across Europe are actively narrowing the conditions under which PFAS-based agents can be used, stored, and disposed of.

Hydrogel is formulated without PFAS, and analytical testing found PFAS at less than 1 part per billion. It is designed for the fire classes where PFAS-based foams have traditionally been specified. When evaluating alternatives, keep four questions separate: chemical composition, environmental safety, firefighting performance, and any approvals your application requires. Confirm the current regulatory position in each market you serve.

The Hydrogel product page provides full technical and regulatory detail for procurement and compliance evaluation.

Related Articles

Harry Verbakel