How do lithium-ion battery fires start and spread?

Lithium-ion battery fires start when internal heat builds up faster than a cell can dissipate it, triggering a self-sustaining chemical chain reaction known as thermal runaway. Once that process begins, the fire can spread quickly, release toxic gases, and resist some conventional extinguishing methods. The sections below answer the key questions about how these fires start, how they behave, and why they are a serious challenge in a growing range of environments.

What triggers thermal runaway in lithium-ion batteries?

Thermal runaway starts when a cell’s internal temperature rises to the point where heat-generating reactions accelerate faster than the battery can release heat. The result is a self-reinforcing cycle: rising temperature drives more reactions, which produce more heat. Three primary causes initiate this process: mechanical damage, thermal abuse, and electrical misuse.

Mechanical damage

Impact, crushing, or penetration can deform the separator that keeps a cell’s electrodes apart. If the separator fails, the electrodes make direct contact and cause an internal short circuit. The resulting current surge generates intense localised heat almost instantly, and thermal runaway can follow within seconds.

Thermal abuse and overheating

Excessive external heat from a nearby fire, direct sunlight, or a poorly ventilated enclosure can push cell temperature beyond safe operating limits. As internal materials decompose, they release energy and flammable gases, adding to the heat already present. This matters most in battery storage systems, where many cells share a confined space.

See where Hydrogel fits your fire-safety strategy
From lithium-ion batteries to existing water-based suppression systems, speak with Anogas about your application.

Discuss your application

Electrical misuse

Overcharging forces more lithium ions into the anode than it can safely hold, so metallic lithium deposits on the electrode surface. This degrades the cell and can create internal short circuits. Deep discharging or using incompatible charging equipment can also destabilise the electrochemical balance inside the cell. Manufacturing defects can introduce the same vulnerabilities from the outset, even in cells that have never been misused.

How fast does a lithium-ion battery fire spread?

A lithium-ion battery fire can spread from one failing cell to an entire pack within minutes. In large energy storage systems, propagation between cells can be even faster. The mechanism is thermal propagation: heat from one cell passes to its neighbours through direct contact, radiated heat, and hot gas release, triggering thermal runaway in sequence.

The speed of spread depends on cell chemistry, pack design, ambient temperature, and whether thermal management or fire suppression is in place. In tightly packed configurations, such as electric vehicle battery packs or wall-mounted energy storage units, cells have little separation. Once one cell enters thermal runaway and its casing ruptures, hot gases and direct heat contact can push adjacent cells past their critical temperature quickly.

Propagation does not need an open flame. Heat transfer alone can destabilise neighbouring cells, and by the time flames are visible the cascade may be well advanced. This is why early intervention and sustained cooling matter. Stopping the spread means removing heat from surrounding cells before they reach their own thermal runaway threshold, not just putting out the visible fire.

What gases and hazards are released during a battery fire?

During a lithium-ion battery fire, cells release a mixture of flammable, toxic, and corrosive gases as internal materials decompose. The most significant are hydrogen, methane, and hydrogen fluoride. Hydrogen and methane increase the risk of explosion and sustained combustion. Hydrogen fluoride is acutely toxic and corrosive, and it endangers anyone nearby, including emergency responders.

Thermal runaway can produce temperatures of around 850 degrees Celsius or higher, depending on cell chemistry and state of charge. Gas release is not limited to the period of visible burning. It can continue after flames have been suppressed, so an apparently extinguished battery may still present an inhalation and ignition hazard.

This is why monitoring after suppression matters as much as the initial response. Extinguishing visible flames does not necessarily end internal heating, gas release, or the risk of reignition. Monitoring periods and cooling times depend on the battery, its state of charge, the damage sustained, and the environment, so assess each incident individually and follow the guidance of the battery manufacturer and the responding fire service. As a general principle, keep the area restricted and ventilated, and transfer the affected battery to a water-filled containment vessel or an isolated, well-ventilated area away from combustible materials. Do not treat extinguishment as confirmation that a battery is safe to reuse, store, transport, or dispose of.

Which environments are at highest risk from lithium-ion battery fires?

The highest-risk environments are those where large numbers of cells are stored, charged, or operated close together, particularly in confined or poorly ventilated spaces. These include warehouses storing e-bikes, power tools, or consumer electronics, EV charging facilities, energy storage installations, maritime vessels, and recycling facilities handling electronic waste.

Residential buildings are an increasingly significant risk as e-bikes, e-scooters, and home battery storage become more common. A single e-bike battery charging overnight in a hallway or stairwell can block escape routes if thermal runaway occurs. The confined space concentrates toxic gases and heat, and the fire can reach the building structure before occupants are aware of the danger.

Industrial and logistics environments carry a different but equally serious risk. Large warehouses may hold thousands of battery-powered devices or battery packs in racking. If thermal runaway begins in one unit, the density of surrounding stock and the energy stored can make rapid suppression difficult. The same applies to recycling facilities, where damaged or partially discharged batteries from many sources are processed alongside other combustible materials.

EV charging infrastructure is a growing concern in public and private settings. In underground or multi-storey car parks, thermal runaway in one vehicle can expose adjacent vehicles to radiated heat and hot gases where ventilation is limited and evacuation is complicated. As the global fleet of electric vehicles grows, the number of such incidents is expected to rise.

Why are lithium-ion battery fires so difficult to extinguish?

Lithium-ion battery fires are difficult to extinguish because the energy driving them comes from inside the cells, not from an external fuel source. Conventional agents can suppress visible flames, but flame suppression is not the same as battery stabilisation. The internal reactions that sustain thermal runaway may continue, so the fire can reignite even after it appears to be out.

Each conventional agent has strengths and limits. Water cools effectively and is widely available, but it may not reach cells inside an enclosed pack, where the heat is generated. Dry chemical powder can knock down flames quickly but provides no sustained cooling. CO2 can displace oxygen around a flame but also provides little cooling. Foam agents have historically been used for their film-forming properties, but those containing PFAS are being phased out in Europe under Regulation (EU) 2025/1988, with a complete ban expected by 2031. This increases demand for alternatives that do not rely on these persistent compounds.

The challenge is compounded because a lithium-ion battery fire is a sequence of linked problems: visible flames, extreme heat, toxic and flammable gas release, thermal propagation to adjacent cells, and reignition risk after suppression. An effective response has to address all of these, not only the flames.

Hydrogel is a water-based agent containing modified natural clay. It works by cooling, and its viscosity is heat-responsive, which is intended to keep the agent in contact with hot surfaces rather than running off. How Hydrogel works explains the mechanism in more detail. Its performance still depends on access to the battery, the enclosure design, the battery configuration, and how the agent is delivered. An externally applied agent will not necessarily reach every cell inside a sealed pack or stop every internal reaction, so Hydrogel is best treated as one part of a wider fire-safety response. Hydrogel Shield is a separate product intended for longer-term containment, to help prevent reignition of damaged or extinguished batteries.

When evaluating a suppression solution, assess the complete setup: the battery configuration, enclosure, agent quantity, discharge arrangement, coverage, operating temperature, compatibility with existing systems, and any required approvals. Verify the specific test evidence and certification status for the product and application in question. For more on how the mechanisms address thermal runaway, see the thermal runaway blocker page, which covers sustained cooling and its role in reducing reignition risk after suppression.