To stop thermal runaway from spreading, cool the affected cells quickly, isolate them from adjacent cells, and manage the flammable gases that drive cascading failure. The aim is to interrupt the chain reaction before heat from one failing cell reaches its neighbours. The sections below explain how thermal propagation works and what can slow or stop it.
What happens when thermal runaway spreads to adjacent cells?
When thermal runaway spreads, heat from one failing cell transfers to neighbouring cells and triggers a cascade known as thermal propagation. Each cell that enters runaway releases more heat, flammable gas, and pressure, which accelerates the failure of the cells around it. Without intervention, a whole battery pack can fail within seconds to minutes.
A lithium-ion cell becomes unstable once its temperature exceeds safe operating limits. Mechanical damage, overheating, or improper charging can start the process. As the cell heats, internal materials decompose, the casing can rupture, and gases including hydrogen, methane, and hydrogen fluoride are released. Hydrogen and methane raise the risk of fire and explosion. Hydrogen fluoride is toxic and corrosive. Gas release can continue after visible flames have gone, so the hazard outlasts the fire.
Temperatures during thermal runaway can reach approximately 850 to 1500 degrees Celsius. At that level, suppression that targets only visible flames is not enough, because the energy sustaining the incident comes from reactions inside the cells. Stopping the spread means addressing both heat transfer between cells and the chemical instability driving the reaction.
Why is thermal runaway so difficult to extinguish?
Thermal runaway is difficult to extinguish because the energy source is inside the cell. In a conventional fire, removing fuel or oxygen breaks the combustion triangle. A cell in thermal runaway generates its own heat and flammable gases from decomposing internal materials, so excluding external oxygen does not stop the reaction.
Extinguishing flames is also not the same as stabilising the battery. Internal heating, gas release, and the risk of reignition can continue after the visible fire is out.
Several factors add to the difficulty. Heat moves quickly between cells through conduction, radiation, and direct contact, so a fire can spread faster than suppression agent can be applied. Flammable and toxic gases keep releasing after flames are suppressed, which sustains ignition risk. Residual heat trapped in a pack can also remain high enough to cause reignition long after the fire appears to be out.
Conventional agents each have a role and each have limits. Water cools effectively on contact, but it can run off before sustained cooling takes effect and may not reach cells inside an enclosed pack. Dry powder and standard foam can suppress flames but do little to cool the battery itself. Some foams have relied on PFAS-based compounds, which are being phased out under European regulation because of their environmental persistence. Battery fires therefore call for an agent chosen for the application, such as lithium-ion battery fire suppression, rather than a general-purpose extinguishing approach.
What suppression methods are most effective against thermal runaway?
Effective suppression of thermal runaway combines rapid cooling, thermal insulation of the cells, and control of flammable gases. No single mechanism is sufficient. A suppression plan should cover the whole incident, from initial flame control through to the period when reignition is possible.
A multi-mechanism approach is needed because thermal runaway presents several threats at once: extreme heat, flammable gas release, toxic compounds, and continuing chemical instability. An agent that addresses more than one of these is more useful than one that addresses only flames.
Hydrogel, developed by Anogas, is a water-based agent containing modified natural clay. Its viscosity responds to heat: it is a low-viscosity liquid when applied and becomes more viscous on hot surfaces. This is intended to keep the agent in contact with the battery instead of running off, which supports sustained cooling and a degree of thermal insulation. You can read more about how it works on the Hydrogel mechanism page.
Hydrogel’s reach depends on access. An externally applied agent cannot be assumed to reach cells inside an enclosed pack or to stop every internal reaction. Performance depends on the battery configuration, how the agent is delivered, and whether it can get to the affected cells.
In practice, direct the agent at visible flames first, then apply it to the surface of the battery pack. Where the pack design allows, agent that reaches the internal structure can provide cooling closer to the source of the reaction. Continue to monitor the battery after extinguishment. A period of 20 minutes is a common minimum, but the right duration depends on the battery and the incident.
How does cooling speed affect thermal runaway containment?
Cooling speed is one of the most important factors in containment. The faster a failing cell is cooled, the less likely heat is to reach adjacent cells and start a cascade. Slow or insufficient cooling lets propagation outpace suppression and can turn a single-cell incident into a full pack failure.
The difficulty is keeping cooling contact on surfaces that are extremely hot and often irregular. Water cools quickly on first contact but runs off rapidly, which limits its sustained effect. An agent that adheres to hot surfaces maintains a continuous cooling layer. That is more effective at limiting heat transfer to neighbouring cells than repeated short bursts of an agent that runs off.
Cooling also matters after the flames are out. Residual heat in a pack can stay high for an extended period. Common guidance is to monitor the battery for at least 20 minutes after extinguishment and to allow a cooling period of around 48 hours before disposal. Treat both figures as starting points and confirm them against the battery type, the incident, and the applicable guidance. Applying agent in controlled intervals, rather than as one large volume, helps maintain a consistent cooling layer.
The quantity of agent required scales with the size of the battery system. As example figures, small devices such as smartphones and laptops may need a minimum of 2 litres, and medium systems such as e-bikes and power tools at least 6 litres. Smaller industrial installations may need 25 to 50 litres, and large-scale battery systems 300 to 10,000 litres or more. These are indicative values for particular applications, not universal rules, so assess the battery configuration and delivery method before sizing a system.
What role does battery pack design play in preventing propagation?
Pack design strongly influences how quickly thermal runaway spreads. Thermal barriers between cells, venting systems, and physical separation can slow propagation and buy time for suppression. No design feature removes the risk entirely, so suppression capability remains essential.
Protective enclosures around large battery systems create a particular problem, because they can block direct access to the source of the fire. In these cases the agent may need to be applied from a safe distance to suppress and contain the fire until emergency services arrive. Assess the enclosure design, the nozzle and discharge arrangement, coverage, and the quantity of agent together, and verify that the complete setup works for the installation. Do not assume that an existing sprinkler system will work with a different agent without engineering and approval checks.
Pack design also affects gas accumulation. Enclosed systems can trap flammable and toxic gases released during thermal runaway, which increases the risk of explosion and poisoning. Audible signs such as hissing or sizzling indicate that gas release is continuing even after flames are controlled. Treat a pack as stabilised only when no visible flames remain, no new flames appear, and audible gas emissions have stopped.
When should a lithium-ion battery fire be considered a reignition risk?
A lithium-ion battery fire should be treated as a reignition risk whenever residual heat, continuing chemical activity, or gas release is present, even after visible flames have been suppressed. Reignition is one of the most serious challenges in battery fires because a battery can look stable while still holding enough internal energy to ignite again.
Signs of elevated reignition risk include hissing or sizzling from the battery, visible steam or vapour, high surface temperatures, and any renewed flame. Flammable gas accumulating near a hot battery surface creates the conditions for reignition.
Sustained suppression matters during this period. An agent that continues to insulate the surface, restrict oxygen, and reduce flammable gas concentrations after initial extinguishment gives better protection against reignition than one that dissipates quickly. No agent guarantees that reignition will not occur. After extinguishment, move the affected battery to a water-filled containment vessel or store it in a well-ventilated area away from combustible materials, restrict access, and monitor it. Monitoring for at least 20 minutes and a cooling period of at least 48 hours before disposal are commonly cited minimums. Extinguishment alone does not make a battery safe to reuse, store, transport, or dispose of.
For longer-term containment of damaged or extinguished batteries, Hydrogel Shield is intended to help prevent reignition, while Hydrogel is used for cooling and initial fire suppression. Facilities that manage multiple battery systems, such as EV charging sites, warehouses with e-bikes or power tools, and energy storage installations, should compare their options against these roles. Fixed fire suppression systems that use agents designed for sustained cooling are generally better suited to high-density battery environments than portable extinguishers alone. For smaller-scale applications, handheld extinguishers provide a first-response option for initial flames. In either case, confirm the test evidence and approvals that apply to your specific equipment and installation.
Related Articles
- What causes re-ignition in battery fires and how do you prevent it?
- What is the safest fire suppression agent for the environment?
- What Is Hydrogel and How Does It Work in Fire Suppression?
- How Hydrogel Effectively Extinguishes Lithium-Ion Battery Fires
- How Hydrogel Compares with Traditional Fire Suppression Agents