To stop thermal runaway from spreading, you need to rapidly cool the affected battery cells, physically isolate them from adjacent ones, and suppress the flammable gases that fuel cascading failure. The key is acting fast enough to interrupt the chain reaction before heat from one failing cell reaches its neighbours. The sections below answer the most important questions about how thermal propagation works and what actually stops it.
What happens when thermal runaway spreads to adjacent cells?
When thermal runaway spreads, heat from one failing battery cell transfers to neighbouring cells, triggering a cascading sequence of failures known as thermal propagation. Each cell that enters runaway releases additional heat, flammable gases, and pressure, accelerating the collapse of surrounding cells. Without intervention, the entire battery pack can fail in a matter of seconds to minutes.
The internal chemistry of a lithium-ion cell becomes dangerously unstable once temperatures rise beyond safe operating limits. Mechanical damage, overheating, or improper charging can destabilise a cell and start the process. As the cell temperature climbs, internal materials decompose, the casing can rupture, and gases including hydrogen, methane, and hydrogen fluoride are released. Hydrogen and methane increase flammability and explosion risk; hydrogen fluoride is toxic and corrosive. Critically, gas release can continue even after visible flames have disappeared, meaning the hazard extends well beyond what is visible.
Temperatures during thermal runaway can reach approximately 850 to 1500 degrees Celsius. At those extremes, conventional fire suppression approaches that target only visible flames are insufficient, because the energy sustaining the incident originates from reactions inside the cells themselves. Stopping the spread requires addressing both the heat transfer between cells and the chemical instability driving the reaction.
Why is thermal runaway so difficult to extinguish?
Thermal runaway is difficult to extinguish because the energy source is internal to the battery cell itself. Unlike a conventional fire, where removing fuel or oxygen can break the combustion triangle, a battery in thermal runaway generates its own heat and flammable gases from decomposing internal materials. Cutting off external oxygen is not enough to stop the reaction.
Several factors compound the difficulty. First, the heat generated by one cell transfers rapidly to adjacent cells through conduction, radiation, and direct contact, meaning the fire can spread faster than suppression agents can be applied. Second, flammable and toxic gases continue to be released even after visible flames are suppressed, creating ongoing ignition risks. Third, residual heat trapped inside a battery pack can remain high enough to trigger reignition long after the initial fire appears to be out.
Conventional extinguishing agents such as water, standard foam, and dry powder can suppress visible flames but often cannot penetrate the battery structure to address the internal chemical reactions. Water applied in large quantities can cool the exterior but may run off before sustained cooling takes effect. Foam agents historically used PFAS-based compounds, which are now being phased out under European regulation due to their environmental persistence. These limitations mean that a purpose-built approach to lithium-ion battery fire suppression is needed rather than a general-purpose extinguishing agent.
What suppression methods are most effective against thermal runaway?
The most effective suppression methods for thermal runaway combine rapid cooling, physical insulation of battery cells, gas suppression, and chemical stabilisation of reactive lithium ions. No single mechanism is sufficient on its own. Effective battery fire suppression addresses the full lifecycle of the incident, from initial flame control through to reignition prevention.
A multi-mechanism approach is necessary because thermal runaway involves simultaneous threats: extreme heat, flammable gas release, toxic compounds, and ongoing chemical instability. Suppression agents that work across all of these dimensions simultaneously are significantly more effective than those targeting only one.
Hydrogel, developed by Anogas, is engineered specifically around this multi-mechanism principle. Its temperature-sensitive gel formation means it transforms from a low-viscosity liquid into a viscous substance when exposed to heat, allowing it to adhere to hot battery surfaces rather than running off. This sustained contact enables five simultaneous suppression mechanisms: rapid cooling, thermal isolation, gas suppression and neutralisation, lithium-ion stabilisation through modified clay particles that bind reactive lithium ions, and reignition prevention through sustained insulation and chemical stabilisation. You can read more about how each mechanism works on the Hydrogel mechanism page.
For practical application, the suppression agent should be directed toward visible flames first, then applied to the battery pack surface. Where possible, allowing the agent to penetrate the internal battery structure provides localised cooling at the source of the reaction. Monitoring should continue for at least 20 minutes after extinguishment, since reignition risk remains elevated during that period.
How does cooling speed affect thermal runaway containment?
Cooling speed is one of the most critical factors in thermal runaway containment. The faster the temperature of a failing cell can be reduced, the lower the probability that heat will transfer to adjacent cells and trigger cascading failure. Slow or insufficient cooling allows thermal propagation to outpace suppression, turning a single-cell incident into a full pack failure.
The challenge is maintaining effective cooling contact with surfaces that are extremely hot and often irregular in shape. Water alone cools quickly on initial contact but runs off rapidly, reducing its sustained effectiveness. A suppression agent that adheres to hot surfaces maintains a continuous cooling layer, which is more effective at preventing heat transfer to neighbouring cells than repeated short bursts of a runoff-prone agent.
Sustained cooling also matters after visible flames are extinguished. Residual heat within a battery pack can remain dangerously high for an extended period. Industry guidance recommends a minimum cooling period of 48 hours before disposal of an affected battery, and a minimum observation period of 20 minutes post-extinguishment to detect signs of renewed instability. Applying suppression agents in controlled intervals rather than a single large volume helps maintain a consistent cooling layer throughout this period.
The quantity of suppression agent required also scales significantly with battery system size. Small devices such as smartphones and laptops may require a minimum of 2 litres, while medium systems such as e-bikes and power tools need at least 6 litres. Smaller industrial installations may require 25 to 50 litres, and large-scale battery safety systems can require 300 to 10,000 litres or more.
What role does battery pack design play in preventing propagation?
Battery pack design plays a significant role in determining how quickly thermal runaway spreads from one cell to the rest of the pack. Design features such as thermal barriers between cells, venting systems, and physical separation can slow propagation and buy time for suppression. However, no design feature eliminates the risk entirely, and suppression capability remains essential.
Protective enclosures around large battery systems present a specific challenge for fire suppression: they can prevent direct access to the ignition source. In these situations, suppression agents may need to be applied from a safer distance to suppress and contain the fire until emergency services arrive. This is a practical constraint that affects both suppression strategy and the choice of agent, since agents that can be applied effectively at distance and still adhere to surfaces are more suitable than those requiring direct contact.
Pack design also affects gas accumulation. Enclosed battery systems can trap flammable and toxic gases released during thermal runaway, increasing explosion and poisoning risk. Even after visible flames are controlled, audible signs such as hissing or sizzling indicate ongoing gas release. A battery pack should only be considered stabilised when no visible flames remain, no new flame eruptions occur, and audible gas emissions have stopped.
When should a lithium-ion battery fire be considered a reignition risk?
A lithium-ion battery fire should be considered a reignition risk whenever residual heat, ongoing chemical activity, or continued gas release is present, even after visible flames have been suppressed. Reignition is one of the most serious challenges in battery fire incidents precisely because the battery can appear stable while still retaining enough internal energy to reignite.
The conditions that indicate elevated reignition risk include audible hissing or sizzling sounds from the battery, visible steam or vapour, elevated surface temperatures, and any renewed flame activity. Gas release can continue after the fire appears extinguished, and flammable gases accumulating near a still-hot battery surface create exactly the conditions needed for reignition.
Sustained suppression is essential during this period. A suppression agent that continues to insulate the battery surface, restrict oxygen availability, and reduce flammable gas concentrations after initial extinguishment provides meaningfully better reignition protection than one that dissipates quickly. After extinguishment, the affected battery should be transferred to a water-filled containment vessel or stored in a well-ventilated area, isolated from combustible materials, and monitored for a minimum of 20 minutes. A cooling period of at least 48 hours is recommended before disposal.
For facilities managing multiple battery systems, such as EV charging infrastructure, warehouses with e-bikes or power tools, or energy storage installations, having a suppression solution that addresses reignition as a specific design objective is important. Fixed fire suppression systems using agents designed for sustained cooling and reignition prevention offer a more reliable response than portable extinguishers alone in high-density battery environments. For smaller-scale applications, handheld extinguishers filled with a purpose-built battery suppression agent provide a first-response option that addresses both initial flames and the reignition window that follows.